![Precor C546 Service Manual Download Page 42](http://html1.mh-extra.com/html/precor/c546/c546_service-manual_1594685042.webp)
C546 Elliptical Fitness Crosstrainer
Page 42
6.
If you have performed all of the above tests and the lift system is still not functioning, call
Precor Technical Support.
7.
Set the circuit breaker in the “off” position. Remove the F2 (2 amp slow blow) fuse from the
lower PCA. Measure the fuse with an ohmmeter. The measurement should be 1
Ω
or less. If
the fuse is good, re-insert the fuse and skip to step 9. If the fuse is open (
∞
) or significantly
high, replace the fuse. Before operating the lift motor it is necessary to perform a continuity
test on the lift motor.
8.
Remove the J3 connector from the lower board. Using an ohmmeter, measure between
terminals 1 and 3 of J3, between terminals 1 and 2 of J3 and between terminals 2 and 3 of
J3. The measurements should be approximately 20.5
Ω, 20.5Ω
and 41
Ω,
respectively. If any
of the measurements are significantly low, replace the lift motor. If any of the readings are
open (
∞
) or significantly high, check the lift motor cable and connectors. Repair any wires or
connections that are bad. If the cable and connectors are good, replace the lift motor.
9.
Re-insert the J3 connector in the lower PCA. Set the on/off switch in the “on” position. Using
an AC voltmeter, monitor the voltage between terminals 1 and 2 (red and white wires) of the
J3 connector. Enter the manual program and press the
RAMP
▲
key. The measurement
should be approximately 120 Vac (line voltage). If the voltage is present and the lift motor
moves normally, skip to step 10. The voltage will only be present until such time as an error
occurs. If line voltage is not present skip to step 11. If line voltage is measured but the motor
does not move, replace the lift motor.
10. Monitor terminals 1 and 3 (white and black wires) of J3. Enter the manual program and
press the
RAMP
▼
key. The measurement should be approximately 120 Vac (line voltage).
If the voltage is present and the lift motor moves normally skip to step 12. The voltage will
only be present until such time as an error occurs. If line voltage is measured but the motor
does not move, replace the lift motor.
11. If line voltage is not present in both steps 9 and 10, connect a dc voltmeter between TP3
and TP6 on the Lower PCA (See Diagram 7.2). The DC voltmeter should read
approximately 5.5 Vdc. Walk on the unit and press the
CROSSRAMP
▼
key. The DC
voltmeter should read near 0 Vdc and the ramp should go downward. Connect a dc
voltmeter between TP4 and TP6 on the Lower PCA (See Diagram 7.2). The DC voltmeter
should read approximately 5.5 Vdc. Pedal on the unit and press the
CROSSRAMP
▲
key.
The DC voltmeter should read near 0 Vdc and the ramp should go upward.
12. If all of the voltages in step 11 were correct but the ramp did not move in both directions
replace the LPCA.
13. If one or more of the voltages in step 11 were incorrect the problem is either one of the
interconnect cables or the Upper PCA. If the display does not indicate that the ramp is
moving in both directions when the appropriate
CROSSRAMP
key is pressed the problem is
either the Upper PCA or the keypad (display housing). Use Procedures 6.1, 6.2 and 6.3 to
determine if the problem is an interconnect cable, keypad or Upper PCA.
14. If you have performed all of the above tests and the lift system is still not functioning, call
Precor Technical Support.
Summary of Contents for C546
Page 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Page 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Page 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Page 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Page 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Page 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...