Open the
WindowsCSAFE
program. It may be necessary to set program to find the file you want
to access. On the tool bar menu choose Options, then set
a90
folder. In the box that opens,
locate the folder you downloaded the files to, then hit
OK
.
Now you should ensure that the
COM
port is properly set. Choose
Options
, then
Set COM Port
,
and choose the proper port from the drop down menu.
Using the drop down menu under
Flash Firmware
choose the correct file for the equipment you
are servicing. Ensure that the power to the lower pca is removed, and that the lower pca has no
residual power. Connect the data cable between the computer and the
CSAFE
port on the upper
pca.
Press the
Flash
button, the data box at the bottom of the screen will prompt that upload will occur
when the upper pca is powered. Apply power to the unit. The upper display should not illuminate,
if it does you don't have a proper connection between the computer and the upper pca, or the
lower board was not fully discharged. Check the
COM
port setting and the lower pca, then when
both are correct hit Flash again.
When the connection is properly made the data box will indicate that upload is in progress. The
Progress bar will show the progress of the upload, which may take as much as 5 minutes,
depending on the download speed of the computer.
When the upload is complete, disconnect the cable between the computer and the unit, and
power the unit down, allowing the lower board to completely discharge. Power up the unit, and
verify the software version from the display.
Uploading serial numbers
Entering the serial number into the upper board of the Experience Line equipment, or other upper
pca's, requires downloading and installing the latest version of the
WinCSAFE
software from the
Precor Connection Website. Once the software is installed, follow these steps.
1.
Click on the
WinCSAFE 2.0
icon to open the program.
2.
Click on the
Options
tab and select the correct
Com
port.
3.
Connect the cable from the computer's
RS232 I/O
port to the
CSAFE
port on the
equipment's upper pca.
4.
Be sure to have the equipment powered up for the following steps. If the unit is a self-
powered unit, you must pedal the unit to provide power before the data will be written.
5.
Enter the serial number data into the
Set Serial Number
window.
6.
Click on the Send button to write the information into the equipment.
7.
Using the standard diagnostics routine, verify that the serial number has been written to the
upper pca.
8.