C534i Elliptical Fitness Crosstrainer
Page 26
Procedure 6.3 - Upper Display does not Illuminate
1.
Because this is a self powered unit, the display will not illuminate until the EFX is used or the
optional external power supply is equipped. If the optional external power supply is
equipped, the display should be constantly illuminated. If the optional external power supply
is not equipped, the unit must be used at a stride rate of 20 strides per minute or higher for
the display to illuminate.
2.
If the optional external power supply is not equipped, skip to step 5.
3.
Disconnect the optional external power supply from the EFX and measure between the
inner and outer sleeves of the power supply’s output jack with a DC voltmeter. You should
measure approximately 18 VDC.
4.
If the voltage measured in step 3 was significantly low, replace the optional external power
supply. If the voltage measured in step 3 was 0 Vdc, disconnect external power supply from
its AC outlet and measure the voltage at the AC outlet. If the AC outlet voltage is normal
replace the optional external power supply. If the AC outlet voltage is significantly low or 0
Vdc, the AC system must be inspected by an electrician.
5.
Troubleshoot the generator per Procedure 6.4.
6.
If the generator was found to be good, the problem will be in either the lower PCA, upper
PCA or the upper to lower PCA interconnect cables.
Warning
Because this is a self powered unit, it will either be necessary to either equip the unit with the
optional external power supply or have an assistant pedal on the unit while voltage measure-
ments are being taken. Because of the danger of working on the unit while it is in motion using
the optional external power supply is strongly recommended.
7.
Remove the rear cover and disconnect the interconnect cable from the J2 connector of the
lower PCA.
8.
The following voltage reading must be taken while the unit is in motion. Extreme care must
be taken to keep meter leads, hands, etc. clear of all moving parts. Using a DC voltmeter,
measure the voltage between TP13 (+5D) and TP4 (DGND). Refer to Diagram 6.4. The
voltage measured should be approximately 5 Vdc. If the voltage is significantly low, replace
the lower PCA. Additionally, the DS1 LED should illuminate.
9.
Reconnect the interconnect cable to the J2 connector of the lower PCA and repeat the
voltage measurement in step 8. The voltage measured should be approximately 5 Vdc. If
the voltage is significantly low, the problem is in the upper PCA or the upper to lower PCA
interconnect cables.