C534i Elliptical Fitness Crosstrainer
Page 18
Procedure 5.1 - Measuring the Resistance of a Generator
Caution
If a external power supply is connected to the EFX, disconnect the external power supply from
the EFX before continuing with this procedure.
Procedure
1.
Remove the access cover, top cover, left and right side covers. See Procedure 7.1.
2.
Remove the two screws that retain the black plastic shield. Remove the black plastic shield
from the EFX.
3.
Remove the red battery lead from the lower PCA. See Diagram 5.1.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in Sec-
tion One, Things You Should Know.
4.
Set the ohmmeter to a range that will conveniently read up to 50
Ω
.
5.
Remove the six phase generator connector from the lower PCA, refer to Diagram 5.1.
6.
With an ohmmeter, read between terminals 1 & 2, terminals 1 & 3, terminals 1 & 5, terminals
1 & 6, and terminals 1 & 7 on the six phase generator connector (J1). Each of the readings
should be between 36
Ω
and 40
Ω.
7.
If any of the readings are significantly high or significantly low, remove the intermediate
cable from the generator and perform the same measurements as in step 4 on the
generator connector. If the reading are now correct check and or replace the intermediate
cable refer to Diagram 5.1. If the readings are still incorrect, remove the six phase
generator.
8.
Replace the generator per Procedure 7.10. Reconnect the intermediate cable removed in
step 5 to the replacement generator and the lower PCA.
9.
Reconnect the red battery lead to terminal M6 of the lower PCA.
10. Set the black plastic shield in its mounting position and fasten it with the screws removed in
step 2.
11. Set the right side of the rear cover in it’s mounting position and rotate it clockwise. Ensure
that the cover is fully engaged and fasten it with the screw removed in step 1.