Load List Management
Load List management can be found on the
Home Screen by pressing “Load List”.
The Load List screen presents all of the loads
taken for the active field and crop. For each load
except the active load, both actual and measured
weights are displayed along with other metrics.
The combine total for the field also displays at
the bottom.
Load List Management
A new load can be created by pressing on “+
New Load”. Enter a name for the new load or use
the default name.
A previous load can also be re-activated by
pressing on that load and selecting “Make
Active”.
Loads True-Up
A loads true-up will calculate a new crop
constant for the active field. This crop constant
will continue to be applied to the yield until a
new crop constant is calculated through a new
loads true-up. It is recommended to have at least
three loads, or 25,000 lbs harvested prior to
performing a loads true-up.
Enter the actual weight for a load or the combine
total for the field to perform a loads true-up.
Once the actual weight has been entered, press
“Done”.
Note:
The actual weight for the load or combine
total must be taken from a grain elevator or a
calibrated weight cart to perform an accurate