background image

PD6700-0L1 Field-Mount Loop-Powered Process Meter 

Instruction Manual 

 

14

 

Setting the Tag (

TAG

Any lower display setting that includes a tag will  
require the tag to be entered. 
 

 

 

The fully alphanumeric values for the tag are set  
using the 

RIGHT 

button to select the digit, the 

UP

 and 

RIGHT 

arrow buttons to select the digit reading, and 

the 

ENTER

 button to confirm and select the next digit. 

 

 

Setting Up the Password  
(

PASSWRD

The 

Password

 menu is used to program a five-digit 

password to prevent unauthorized changes to the 
programmed parameter settings. A password 
protected meter will display 

LOCKED

 when the 

MENU

 

button is pressed. 

Locking the Meter 

Enter the 

Password

 menu and program a five-digit 

password. 
For instructions on how to program numeric values 
see 

Setting Numeric Values

, page 

12

.  

 

Record the password for future reference. If 
appropriate, it may be recorded in the space provided. 

Model:  

 

Serial Number: 

 

Password:  

__  __  __  __  __ 

Making Changes to a Password 
Protected Meter 

If the meter is password protected, the meter will  
display the message 

LOCKED

 when the Menu button 

is pressed. Press the Enter button while the message  
is being displayed and enter the correct password to 
gain access to the menu. After exiting the 
programming mode, the meter returns to its password  
protected condition. 
 

 

 

Disabling Password Protection 

To disable the password protection, access the 

Password

 menu and enter the correct password, as 

shown below. 

 

 

 
If the correct five-digit password is entered, the meter 
displays the message 

UNLOCKD

 (

unlocked

) and the 

protection is disabled until a new password is 
programmed. 

If the password entered is incorrect, the meter 
displays the message 

LOCKED

 and returns to Run 

Mode. To try again, repeat the above procedure. 
 

Did you forget the password? 

The password may be disabled by entering a 
master password. If you are authorized to make 
changes, enter the master password 50865 to  
unlock the meter. 

Summary of Contents for vantageview Safe Touch PD6700-0L1

Page 1: ...r Display Display Mountable at 0 90 180 270 SafeTouchTM Through Window Button Programming Display Input in Two Different Scales Simultaneously Great for Level Applications 20 Segment Level Indicator B...

Page 2: ...Precision Digital Corporation All rights reserved Introduction The PD6700 0L1 is a rugged field mount loop powered meter fully featured for demanding applications in harsh environmental conditions Th...

Page 3: ...ing the Meter SCaLe 13 Minimum Input Span 13 Scale Error Message SPN ERR 13 Scaling the Tank Level Indicator PERCENT 13 Configuring the Display DISPLAY 13 Setting the Tag TAG 14 Setting Up the Passwor...

Page 4: ...imensions Side Cross Section View 6 Figure 3 Connector Board 7 Figure 4 Connections without Backlight 8 Figure 5 Connections with Loop Powered Backlight 8 Figure 6 Connections with Externally Powered...

Page 5: ...ntal Operating temperature range 40 to 75 C Storage temperature range 40 to 75 C Relative humidity 0 to 90 non condensing Connections Screw terminals accept 12 to 22 AWG wire Enclosure NEMA 4X IP65 pl...

Page 6: ...e the meter from box Inspect the packaging and contents for damage Report damages if any to the carrier If any part is missing or the meter malfunctions please contact your supplier or the factory for...

Page 7: ...ght from external supply OUTPUT NPN open collector output positive OUTPUT NPN open collector output negative RESET Contact closure alarm acknowledge pull up to 3 VDC RESET Contact closure alarm acknow...

Page 8: ...e to two terminals labeled RESET Connect to a contact closure source such as a relay or a pushbutton as shown in Figure 7 Figure 7 External Alarm Reset Acknowledge Connections Open Collector Output Co...

Page 9: ...rd in the base of the enclosure SafeTouch Button Operation To actuate a button press and remove one finger to the window directly over the marked button area Remove finger to at least 4 inches away fr...

Page 10: ...the Right arrow button to reset the maximum or minimum value while it is being displayed see Up Display Button below Press the Right arrow button to move to the next digit or decimal position during p...

Page 11: ...play Enter Bottom Display menu TAG Tag Display a custom unit or tag VOLUME Volume Display volume VOL TAG Volume Tag Display volume and custom tag PCT HT Percent Height Display percent height PCT TAG P...

Page 12: ...o the previous menu selections Setting Numeric Values The numeric values are set using the RIGHT and UP arrow buttons Press RIGHT arrow to select next digit and UP arrow to increment digit The digit b...

Page 13: ...nearization MULTIPT menu selection prior to scaling and calibration of the meter see Advanced Features Menu ADVANCE on page 15 Scaling the Tank Level Indicator PERCENT The display includes a 20 segmen...

Page 14: ...recorded in the space provided Model Serial Number Password __ __ __ __ __ Making Changes to a Password Protected Meter If the meter is password protected the meter will display the message LOCKED wh...

Page 15: ...Menu Access the Advanced Features Menu by pressing ENTER at the ADVANCE menu in the Main Menu defined on page 11 The Advanced Features Menu is used to select 1 Open collector output configuration OUTP...

Page 16: ...NPUT 1 Input 1 Set volume input 1 on the level display DSPLY 1 Display 1 Set volume display 1 INPUT 2 Input 2 Set volume input 2 on the level display DSPLY 2 Display 2 Set volume display 2 Display Par...

Page 17: ...etween its normal display and ALARM until the alarm condition is cleared The alarm status will show on the display even if the output is not wired Input Signal Filter FILTER The noise filter is availa...

Page 18: ...ve a full scale accuracy of 0 002 or better between 4 and 20 mA in order to maintain the specified accuracy of the meter 2 Allow the meter to warm up for at least 15 minutes before performing the cali...

Page 19: ...s displayed will reset that value to the current display value Press the DISPLAY button a third time and the meter will display LOOP MA on the lower display and the measured input current in milliamps...

Page 20: ...e Diagnostics menu and consult the recommendations described in the following table Troubleshooting Tips Symptom Check Action No display or faint display Check input signal connections Perform hard re...

Page 21: ...tion or increment digit Cycle through maximum minimum and mA display mode ENTER Accept selection value and move to next selection Acknowledge alarms To enter the Advanced Features Menu hold the Menu b...

Page 22: ...8990 www predig com LIM6700L_D SFT087 Ver 1 300 up 07 20 Contact Precision Digital Technical Support Call 800 610 5239 or 508 655 7300 Fax 508 655 8990 Email support predig com Sales Support Call 800...

Reviews: