background image

PD6701 Field-Mount Loop-Powered Feet & Inches Level Meter 

Instruction Manual 

 

19

 

Setting Up the Password  
(

PASSWRD

The 

Password

 menu is used to program a five-digit 

password to prevent unauthorized changes to the 
programmed parameter settings. A password 
protected meter will display 

LOCKED

 when the 

MENU

 

button is pressed. 

Locking the Meter 

Enter the 

Password

 menu and program a five-digit 

password. 
For instructions on how to program numeric values 
see 

Setting Numeric Values

, page 

12

.  

 

Record the password for future reference. If 
appropriate, it may be recorded in the space provided. 

Model:  

 

Serial Number: 

 

Password:  

__  __  __  __  __ 

 

Making Changes to a Password 
Protected Meter 

If the meter is password protected, the meter will  
display the message 

LOCKED

 when the Menu button 

is pressed. Press the Enter button while the message  
is being displayed and enter the correct password to 
gain access to the menu. After exiting the 
programming mode, the meter returns to its password  
protected condition. 

 

Disabling Password Protection 

To disable the password protection, access the 

Password

 menu and enter the correct password,  

as shown below. 
 

 

 

If the correct five-digit password is entered, the meter 
displays the message 

UNLOCK

D

 (

unlocked

) and the 

protection is disabled until a new password is 
programmed. 

If the password entered is incorrect, the meter 
displays the message 

LOCKED

 and returns to Run 

Mode. To try again, repeat the above procedure. 
 

Did you forget the password? 

The password may be disabled by entering a 
master password. If you are authorized to make 
changes, enter the master password 50865 to  
unlock the meter. 

 

 

 

FT

IN

FT

IN

Summary of Contents for PD6701

Page 1: ...Tag Volume or Percent Display Level in Feet Inches and Volume Percent or Decimal Height Simultaneously Display Mountable at 0 90 180 270 SafeTouchTM Through Window Button Programming 20 Segment Tank...

Page 2: ...1 is a rugged field mount loop powered indicator specifically designed for level applications in harsh environmental conditions The meter displays level in easy to read and understand feet inches and...

Page 3: ...es 12 Scaling the Meter SCaLe 13 Selecting Inch Fraction Display Mode FRACTN 13 Scaling the Tank Level Indicator PERCENT 13 Configuring the Lower Display DISPLAY 14 Setting the Tag TAG 14 Advanced Fea...

Page 4: ...e Dimensions Side Cross Section View 6 Figure 3 Connector Board 7 Figure 4 Connections without Backlight 8 Figure 5 Connections with Loop Powered Backlight 8 Figure 6 Connections with Externally Power...

Page 5: ...ower is lost Normal Mode Rejection 64 dB at 50 60 Hz Environmental Operating temperature range 40 to 75 C Storage temperature range 40 to 75 C Relative humidity 0 to 90 non condensing Connections Scre...

Page 6: ...rt damages if any to the carrier If any part is missing or the meter malfunctions please contact your supplier or the factory for assistance Pre Installed Conduit Plug The PD6701 is supplied with two...

Page 7: ...klight from external supply OUTPUT NPN open collector output positive OUTPUT NPN open collector output negative RESET Contact closure alarm acknowledge pull up to 3 VDC RESET Contact closure alarm ack...

Page 8: ...nnections are made to two terminals labeled RESET Connect to a contact closure source such as a relay or a pushbutton as shown in Figure 7 Figure 7 External Alarm Reset Acknowledge Connections Open Co...

Page 9: ...n Operation To actuate a button press and remove one finger to the window directly over the marked button area Remove finger to at least 4 inches away from the window in between button activations Saf...

Page 10: ...meter Right Reset Button Press the Right arrow button to reset the maximum or minimum value while it is being displayed see Up Display Button below Press the Right arrow button to move to the next di...

Page 11: ...1 8th Set display for 1 8th inch fractions PERCENT Percent Scale the tank indicator full and empty values 0 PCT 0 Percent Set the tank empty value 100 PCT 100 Percent Set the tank full value DISPLAY D...

Page 12: ...es made to settings prior to pressing ENTER are not saved Press the MENU button during Programming Mode to return to the previous menu selections Setting Numeric Values The numeric values are set usin...

Page 13: ...ng of the meter The minimum span is 0 10 mA Scale Error Message SPN ERR If the minimum span is not maintained the meter will show a span error SPN ERR and revert to input 2 allowing the appropriate in...

Page 14: ...ate second scale of the input process variable This is configured in Volume Display Scaling VOLSCAL on page 17 Percent full height shows the percent full of the tank height level indicator programmed...

Page 15: ...e Advanced features menu functions and messages in the order they appear in the menu Display Parameter Action Setting OUTPUT Output Enter output menu OFF Off Disable output ALARM Alarm Output Enter al...

Page 16: ...ibration parameters ICAL Internal Calibration Enter internal reference calibration 4mA 4 mA Calibrate input at 4 mA 20mA 20 mA Calibrate input at 20 mA ERRSPAN Error Span Error with calibration point...

Page 17: ...y and ALARM until the alarm condition is cleared The alarm status will show on the display even if the output is not wired Input Signal Filter FILTER The noise filter is available for unusually noisy...

Page 18: ...ment while the meter is accepting the signal After the signal is accepted the meter displays 20 mA Apply a 20 000 mA signal and press ENTER The display flashes for a moment while the meter is acceptin...

Page 19: ...meter will display the message LOCKED when the Menu button is pressed Press the Enter button while the message is being displayed and enter the correct password to gain access to the menu After exiti...

Page 20: ...ayed will reset that value to the current display value Press the DISPLAY button a third time and the meter will display LOOP MA on the lower display followed by the measured input current in milliamp...

Page 21: ...ostics menu and consult the recommendations described below Troubleshooting Tips Symptom Check Action No display or faint display Check input signal connections Perform hard reset by shorting S and S...

Page 22: ...lection or increment digit Cycle through maximum minimum and mA display mode ENTER Accept selection value and move to next selection Acknowledge alarms To enter the Advanced Features Menu hold the Men...

Page 23: ...655 8990 www predig com LIM6701_E SFT087 Ver 1 300 up 07 20 Contact Precision Digital Technical Support Call 800 610 5239 or 508 655 7300 Fax 508 655 8990 Email support predig com Sales Support Call 8...

Reviews: