Helios Large Display Analog Input Batch Controller Instruction Manual
PD2-6210
50
Advanced Features Menu
To simplify the setup process, functions not needed for most applications are located in the
Advanced
Features
menu.
Press and hold the Menu button for three seconds to access the advanced features of the meter. This
cannot be done during a batch process as all functions other than STOP are disabled during a batch
process, including the
Menu
button.
Advanced Features Menu & Display Messages
The following table shows the functions and messages of the
Advanced Features
menu in the order they
appear in the menu.
Display
Parameter
Action/Setting
filtEr
Filter
Set noise filter value
bypASs
Bypass
Set filter bypass value
Round
Round
Set the rounding value for display variables
seriAl
Serial
Set serial communication parameters
SlaveId
Slave ID
Set slave ID or meter address
baud
Baud rate
Select baud rate
Tr dLY
Transmit delay
Set transmit delay for serial communication
Parity
Parity
Select parity: Even, Odd, or None with 1 or 2 stop bits
t-byt
Time byte
Set byte-to-byte timeout
SelEct
Select
Enter the Select menu (function, cutoff, out)
Functn
Signal input
conditioning
Select linear, square root, programmable exponent, or round
horizontal tank function
Linear
Linear
Set meter for linear function and select number of linearization
points
No PtS
Number of points
Set PV1 for 2 to 32-point linearization
Set PV2 for 2 to 8-point linearization
Square
Square root
Set meter for square root extraction
Prog E
Programmable
exponent
Set meter for programmable exponent and enter exponent
value
CutofF
Cutoff
Set low-flow cutoff