PD2-6100
Large Display Strain Gauge Meter Instruction Manual
59
Factory Defaults & User Settings
The following table shows the factory setting for most of the programmable parameters on the meter.
Parameter
Display
Default Setting
Input type
Polar
Polar = Uni
Input Range
range
Range = 30mV
Ratiometic
ratio
Ratio = Yes
Dual-scale
d-SCAl
No (Single scale)
Filter
filter
70
Bypass
bypass
0.2
Rounding
round
1
Function
Functn
Linear
Number of points
No Pts
2
Programming
prog
Scale
Input 1
InP 1
0.00 mV
Display 1
Dis 1
0.00
Input 2
InP 2
100.00 mV
Display 2
Dis 2
100.00
Decimal point
ddd.ddd
3 places
Cutoff value
CutofF
0.000 (disabled)
Auto-zero
Auto 0
0.05% of Full Scale
Display
assignment
Dsplay
Upper display
big
PV: Process
variable
Lower display
Little
Eng units: mV
Display intensity
d-Inty
8
Relay 1 action
Act 1
Automatic
Relay 1 set point
Set 1
10.00
Relay 1 reset
point
RSt 1
5.00
Relay 2 action
Act 2
Automatic
Relay 2 set point
Set 2
20.00
Relay 2 reset
point
RSt 2
15.00
Relay 3 action
Act 3
Automatic
Relay 3 set point
Set 3
30.00
Relay 3 reset
point
RSt 3
25.00
Relay 4 action
Act 4
Automatic
Relay 4 set point
Set 4
40.00
Relay 4 reset
point
RSt 4
35.00
Fail-safe relay 1
Fls 1
Off
Fail-safe relay 2
Fls 2
Off
Fail-safe relay 3
Fls 3
Off
Fail-safe relay 4
Fls 4
Off
Parameter
Display
Default Setting
On delay relay 1
On 1
0.0 sec
Off delay relay 1
Off 1
0.0 sec
On delay relay 2
On 2
0.0 sec
Off delay relay 2
Off 2
0.0 sec
On delay relay 3
On 3
0.0 sec
Off delay relay 3
Off 3
0.0 sec
On delay relay 4
On 4
0.0 sec
Off delay relay 4
Off 4
0.0 sec
Display 1 analog
out
Dis 1
0.00
Output 1 value
Out 1
4.000 mA
Display 2 analog
out
Dis 2
100.00
Output 2 value
Out 2
20.000 mA
Source analog
output
Source
Process Variable
Overrange output
O-rang
21.000 mA
Underrange
output
u-rang
3.000 mA
Maximum output
mAx
23.000 mA
Minimum output
min
1.000 mA
Slave ID
(Address)
SlavId
247
Baud rate
baud
9600
Transmit delay
Tr dly
10 ms
Parity
Parity
Even
Byte-to-byte
timeout
t-byt
010 (0.1 sec)
F1 function key
F1
Zero
F2 function key
F2
Reset Tare
F3 function key
F3
Tare
F4 Function
F4
Acknowledge relays
Digital input 1
dI 1
Menu
Digital input 2
dI 2
Right arrow/F1
Digital input 3
dI 3
Up arrow/F2
Digital input 4
dI 4
Enter/F3
Digital output 1
dO 1
Alarm 1
Digital output 2
dO 2
Alarm 2
Digital output 3
dO 3
Alarm 3
Digital output 4
dO 4
Alarm 4
Password 1
Pass 1
000000 (unlocked)
Password 2
Pass 2
000000 (unlocked)
Password 3
Pass 3
000000 (unlocked)