Strain Gauge Connections
The following figures show examples of strain gauge connections.
There is a 5-position DIP switch (CONFIG) to set up the input ranges and ratiometric operation.
NOTE:
Refer to Switch Configuration starting on page 13 for proper switch positioning for the
following wiring configurations.
Figure 10. Strain Gauge Powered by
Internal Supply
Figure 11. Strain Gauge Powered by
External Supply
When connecting multiple strain gauges to the meter, each must be wired in parallel. This is typically
done with the use of a junction box.
Figure 12. Multiple Strain Gauges Connected Through Junction Box
EX+
COM
F4
SG+
SG-
INPU T SIGNA L
EX+
EX-
SG-
SG+
EX-
EX+
EX-
SG-
SG+
EX+
SG-
SG+
Up to 12
Load Cells
EX-
Junction Box