Helios Large Display Strain Gauge Meter Instruction Manual
PD2-6100
50
Display
Parameter
Action/Setting
rht
Round
horizontal tank
Set meter for round horizontal tank volume calculation
Inch
Dimension
Calculate volume in gallons
cm
Dimension
Calculate volume in liters
diamr
Diameter
Enter the tank’s diameter in inches
Length
Length
Enter the tank’s length in inches
CutofF
Cutoff
Set low cutoff
Auto 0
Auto Zero
Enter the Auto Zero function (on/off)
AoutPr
Analog output
programming
Program analog output parameters
Source
Source
Select source for the 4-20 mA output
O-rang
Overrange
Program mA output for display overrange
u-rang
Underrange
Program mA output for display underrange
break
Break
Set input break condition operation
mAx
Maximum
Program maximum mA output allowed
min
Minimum
Program minimum mA output allowed
Calib
Calibrate
Calibrate 4-20 mA output (internal reference source used for scaling
the output)
4 mA
4 mA output
Enter mA output value read by milliamp meter with at least 0.001 mA
resolution
20 mA
20 mA output
Enter mA output value read by milliamp meter with at least 0.001 mA
resolution
user
User I/O
Assign function keys and digital I/O
F1
F1 function key
Assign F1 function key
F2
F2 function key
Assign F2 function key
F3
F3 function key
Assign F3 function key
F4
F4 function
Assign F4 function (digital input)
dI I
Digital input 1
Assign digital input 1 – 4, if expansion modules are connected
dO 1
Digital output 1
Assign digital output 1 – 4, if expansion modules are connected
ICal
Internal source
calibration
Enter internal source calibration (used for scaling the meter without
a signal source)
15mv
15 mV
calibration
Calibrate 15 mV input range (internal reference source used for
scaling the input)
20mv
20 mV
calibration
Calibrate 30 mV input range (internal reference source used for
scaling the input)
100mv
100 mV
calibration
Calibrate 150 mV input range (internal reference source used for
scaling the input)
200mv
200 mV
calibration
Calibrate 300 mV input range (internal reference source used for
scaling the input)
stroff
Strain offset
Calibrate the offset of the input circuit
v Lo
mV low
Calibrate low mV input (e.g. 0 mV)
v Hi
mV high
Calibrate high mV input (e.g. 100 mV)
Diag
Diagnostics
Display parameter settings
LED t
LED test
Test all LEDs
Info
Information
Display software and S/N information
Erase
Erase
Delete the MeterView Pro installation files from the meter