ProtEX-MAX PD8-6060 Explosion-Proof Dual-Input Meter Instruction Manual
5
Ordering Information
SunBright Display Models
85-265 VAC Model 12-24 VDC Model Options Installed
PD8-6060-6H0
PD8-6060-7H0
No options
PD8-6060-6H7
PD8-6060-7H7
4 relays & 4-20 mA output
WARNING
- Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
Accessories
Model
Description
PDA1232
RS-232 serial adapter
PDA1485
RS-485 serial adapter
PDA7485-I
RS-232 to RS-422/485 isolated converter
PDA8232-N
USB to RS-232 non-isolated converter
PDA8485-I
USB to RS-422/485 isolated converter
PDX6901
Suppressor (snubber): 0.01 µF/470
, 250 VAC
Specifications
Except where noted all specifications apply to operation at +25°C.
General
Display
Line 1: 0.60" (15 mm) high, red LEDs
Line 2: 0.46" (12 mm) high, red LEDs
6 digits each (-99999 to 999999), with lead
zero blanking
Display
Intensity
Eight user selectable intensity levels
Display
Update Rate
5/second (200 ms)
Overrange
Display flashes
999999
Underrange
Display flashes
-99999
Display
Assignment
Display lines 1 & 2 may be assigned to
process values for Channels A (Ch-A), B
(Ch-B), or C (Ch-C), toggle between (Ch-A
& Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and
Ch-A, Ch-B, & Ch-C), toggle between
Channel & units, show channel gross value
(no tare) or toggle net (tare) and gross
values, show relay set points, max & min
values, or Modbus input. Line 2 may also
be set to show engineering units or be off,
with no display.
Programming
Methods
Four front panel buttons, digital inputs, PC
and MeterView Pro software, or Modbus
registers.
Noise Filter
Programmable from 2 to 199 (0 will disable
filter)
Filter Bypass
Programmable from 0.1 to 99.9% of
calibrated span
Recalibration
All ranges are calibrated at the factory.
Recalibration is recommended at least
every 12 months.
Max/Min
Display
Max/min readings reached by the process
are stored until reset by the user or until
power to the meter is cycled.
Password
Three programmable passwords restrict
modification of programmed settings.
Pass 1: Allows use of function keys and
digital inputs
Pass 2: Allows use of function keys, digital
inputs and editing set/reset points
Pass 3: Restricts all programming, function
keys, and digital inputs.
Non-Volatile
Memory
All programmed settings are stored in non-
volatile memory for a minimum of ten years
if power is lost.
Power
Options
85-265 VAC 50/60 Hz, 90-265 VDC, 20 W
max or 12-24 VDC
10%, 15 W max
Powered over USB for configuration only.
Fuse
Required external fuse: UL Recognized, 5
A max, slow blow; up to 6 meters may
share one 5 A fuse
Isolated
Transmitter
Power Supply
Terminals P+ & P-: 24 VDC
10%.
Selectable for 24, 10, or 5 VDC supply (internal
jumper J4). All models transmitter supply rated
@ 25 mA max.
Normal Mode
Rejection
Greater than 60 dB at 50/60 Hz
Isolation
4 kV input/output-to-power line
500 V input-to-output or output-to-P+ supply
Overvoltage
Category
Installation Overvoltage Category II:
Local level with smaller transient
overvoltages than Installation Overvoltage
Category III.
Environmental
T6 Class operating temperature range Ta =
-40 to 60°C
T5 Class operating temperature range Ta =
-40 to 65°C
Max Power
Dissipation
Maximum power dissipation limited to 15.1
W.
Connections
Screw terminals accept 12 to 22 AWG wire