PD154 & PD158 Vigilante
®
II Annunciators
Instruction Manual
4
QUICK SETUP GUIDE
The following overview details how to set up the annunciator for most
common uses.
Sequence Selection
The two most common sequences are ISA A and ISA F2A. Select the
sequence using the four-position switch on the rear of the unit above the
signal connector. For complete sequence details, see page
31
.
ISA A
ISA F2A
NO/NC Inputs
Each input can be set for normally open (NO) or normally closed (NC)
contacts. Each input channel is programmed individually. The default
setting is for all inputs to be NO.
To set inputs to NC:
1. Press and hold
ACK
and
RESET
for 3 seconds until all LEDs
cycle.
2. Press
ACK
within 3 seconds of release. All LEDs will blink. If
ACK
is not pressed within 3 seconds the unit will return to run
mode.
3. Press
ACK
again within 3 seconds of release. If
ACK
is not
pressed within 3 seconds the unit will return to run mode.
The LED for the channel being programmed will display brightly on or
off. All other channel indication LEDs will be at low intensity to indicate
programming mode.
4. Press
the
RESET
pushbutton to turn LED 1 off for a NO input,
or on for a NC input for channel 1.
5. Press
ACK
to accept the input type and program channel 2.
6. Repeat steps 4 and 5 for all input channels.
7. Press and hold
ACK
for five seconds to return to normal
operation with the programmed input types.