Helios Large Display Dual-Input Meter Instruction Manual
PD2-6060
56
Display
Description
F On 1
*
Force relay 1 (*through 4) into the
on state. This function is used in
conjunction with a digital input
expansion module to achieve
interlock functionality. See page 42
for details about interlock relays.
Contrl
Directly access the control menu
disabl
Disable the selected function key or
digital I/O
AcH
Acknowledge all active relays that
are in a manual operation mode
such as auto-manual or latching
Display
Description
Reset
Directly access the reset menu
nmenu
Mimic the menu button functionality
(digital inputs only)
rigHt
Mimic the right arrow/F1 button
functionality (digital inputs only)
up
Mimic the up arrow/F2 button
functionality (digital inputs only)
Enter
Mimic the enter/F3 button
functionality (digital inputs only)
Alnm 1
*
Provide indication when alarm 1
(*through 8) has been triggered
(digital outputs only)
* If math functions are displayed, the math function indicator LED “C” will flash when either A or B
channel is using a tare value (net value).
Tare (
tare
)
The tare function zero’s out the display. In the case of scale weight, tare is used to eliminate container
weight and provide net weight readings. There are two tare functions; Capture Tare for channel A and B,
and Reset Tare. Display channel indicator letter flashes when a tare is used. It will flash until the tare is
reset.
Gross (without tare) and net (with tare) values can be viewed simultaneously. See page 32.
0.0
lbs
0.2
lbs
0.2
lbs
Before tare
After capture tare
After reset tare
www.
GlobalTestSupply
.com
Find Quality Products Online at: