PD2-6060
Helios Large Display Dual-Input Meter Instruction Manual
47
Display
Parameter Action/Setting
Prog E
Programm
able
exponent
Set meter for
programmable
exponent and enter
exponent value
rht
Round
horizontal
tank
Set meter for round
horizontal tank
volume calculation
Length
Length
Enter the tank’s
length in inches
diamr
Diameter
Enter the tank’s
diameter in inches
nmath
Math
Enter the setup
menu for channel C
math functions
Sunm
Sum
Channel C =
(A+B+P)*F
Dif
Difference
Channel C = (A-
B+P)*F
difabs
Absolute
difference
Channel C =
((Absolute value of
(A-B))+P)*F
Avg
Average
Channel C =
(((A+B)/2)+P)*F
nmulti
Multiplicati
on
Channel C =
((A*B)+P)*F
Divide
Divide
Channel C =
((A/B)+P)*F
Hi-ab
Max of A or
B
C = ((High value of
channel A or
B)+P)*F
Lo-ab
Min of A or
B
C = ((Low value of
channel A or
B)+P)*F
Drauw
Draw
Channel C = ((A/B)-
1)*F
uwAvg
Weighted
avg.
Channel C = ((B-
A)*F)+A
ratio
Ratio
Channel C = (A/B)*F
Ratio2
Ratio 2
C = (((B-A)/A)+P)*F
Concen
Concentrati
on
Channel C =
(A/(A+B))*F
Const
Constant
Constant used in
channel C math
adder
Adder
Addition constant
used in channel C
math calculations
(P)
Display
Parameter Action/Setting
factor
Factor
Multiplication
constant used in
channel C math
calculations (F)
CutofF
Cutoff
Set low-flow cutoff
Ch-A
Channel A
Set low-flow cutoff
for Channel A
Ch-b
Channel B
Set low-flow cutoff
for Channel B
AoutPr
Analog
output
programmi
ng
Program analog
output parameters
AOut 1
*
Analog
output 1
Program analog
output 1 (*1-3)
parameters
Source
Source
Select source for the
4-20 mA output
break
Break
Set input break
condition operation
O-rang
Overrange
Program mA output
for display
overrange
u-rang
Underrang
e
Program mA output
for display
underrange
mAx
Maximum
Program maximum
mA output allowed
min
Minimum
Program minimum
mA output allowed
Calib
Calibrate
Calibrate 4-20 mA
output (internal
reference source
used for scaling the
output)
4 mA
4 mA
output
Enter mA output
value read by
milliamp meter with
at least 0.001 mA
resolution
20 mA
20 mA
output
Enter mA output
value read by
milliamp meter with
at least 0.001 mA
resolution
user
User I/O
Assign function keys
and digital I/O
F1
F1 function
key
Assign F1 function
key
F2
F2 function
key
Assign F2 function
key