7 Accessing System Information
Ether232
Plus
User Guide
66
Precidia Technologies Inc.
02-CML000057
Connection with
xxx.xxx.xxx.xxx
stopped
due to connection control
The connection control setting and
signal lines dictate that the session
being established no longer become
established.
Connection with
xxx.xxx.xxx.xxx
dropped
due to connection control
The connection control setting and
signal lines dictate that the session
that was established be dropped.
Configuration changes could not be
saved--restarting system
The configuration failed to be saved
to the unit. This could indicate bad
Flash.
DHCP: address xxx.xxx.xxx.xxx acquired
permanently
DHCP assigned an IP address to the
unit which does not need renewal.
DHCP: address xxx.xxx.xxx.xxx acquired
for xxx seconds
DHCP assigned an IP address to the
unit for the indicated number of sec-
onds. Before expiration, DHCP
attempts to renew the licence. If
unsuccessful, DHCP attempts to
contact another DHCP server on the
network by sending a broadcast mes-
sage. If the unit address is not
renewed, after expiration, it will no
longer have an IP address.
SNTP: Real-time clock updated (offset = x
seconds)
If a Primary server is configured, the
clock is enabled and updates every
five minutes. Its offset is a measure-
ment of the difference between the
internal clock and the real-time
clock. The system uses the offset to
compensate for future time drifts.
SNTP: Unable to update real-time clock
Indicates that the configured server
did not respond to the time request.
Table 7.3: System Log Messages
Message