The Com Port portion of the test will always return “

Com Port... skipped (external 

loopback not found)

” if you are running the Self Test from a local connection and do 

not have an external loopback dongle attached to the 

COM

 port. You must attach a 

loopback dongle and run the Self Test remotely via telnet to test the com port.

Messages that may result from the Com Port test are described in Table 6.1.

6.8

Reset Unit

Reset Unit is useful for troubleshooting, since it allows you to ensure that modem 
connections are dropped correctly. Reset Unit resets the Ether232

Plus

, and drops all 

active modem connections. The Configuration screen is not changed nor is the System 
Log cleared, however, the message “===== Ether232Plus Started =====” is appended 
to the System Log.

Reset Unit allows you to reset the Ether232

Plus

 from a telnet session without saving 

any changes to the configuration menu. 

6.9 SNTP Settings

Simple Network Time Protocol (SNTP) is used to synchronize computer clocks on the 
Internet. Every 5 minutes, a request is sent to the 

Primary Server

. If a response has 

not been received by the unit within one minute, a request is sent to both the 

Primary 

Server

, and the 

Secondary Server

 (if defined). This feature is disabled if the Primary 

IP address is not defined.

The real-time clock timestamp can be viewed in the System Log. Please refer to 
section 7.2 System Log for further information.

Table 6.1: Com Port Self Test Results

Result

Meaning

Com Port... passed

Everything is fine

Com Port... character not received

A transmitted character was not received

Com Port... character not transmitted

The internal port could not transmit

Com Port... skipped (external loop-

back not found)

No loopback dongle found

Com Port... control lines not looped 

back

The DTR/DSR, DTR/DCD lines, if 
present, are not looped back as expected

Com Port... transmitted and received 

characters are different

The data sent is not the same as the data 
received

Summary of Contents for Ether232Plus

Page 1: ...Ether232Plus User Guide Software Version 4 04 00 Document No 02 CML000057 Revision Date 15 MAR 04 Document Revision 2 0 www precidia com...

Page 2: ...ecidia com Disclaimer and Confidentiality Notice The content of this document is furnished for informational use only is subject to change without notice and should not be construed as a commitment by...

Page 3: ...uration 9 2 2 Setting Up the Terminal 10 2 3 Understanding the Configuration Screen 11 2 4 Timeout During Configuration 12 2 5 Resetting to Factory Default Configuration 13 3 Configuring the Ethernet...

Page 4: ...e Access Password 41 Viewing the Access Password 41 Clearing the Access Password 42 5 6 SNMP Server 42 5 7 SNMP Settings 42 5 8 IPsec Tunnels 1 and 2 43 Protocol 44 Secure Address 45 SPI 46 Network Ad...

Page 5: ...L000057 Precidia Technologies Inc iii Appendix A Glossary of Terms and Acronyms A 1 Appendix B Troubleshooting and Support B 1 Appendix C Specifications and Warranty C 1 Appendix D Connecting with Tel...

Page 6: ...Table of Contents Ether232Plus User Guide iv Precidia Technologies Inc 02 CML000057...

Page 7: ...4 Configuring the Serial Port Settings Configure the protocol speed connection control and port information 5 Configuring the Security Settings Configure the remote console and Web passwords SNMP and...

Page 8: ...rver The figure below illustrates an example configuration of the Ether232PPlus in a network Ether232Plus Network Configuration Features The Ether232Plus has many useful features allowing you to Confi...

Page 9: ...ains active COM Port Redirector Software compatibility using the Com Port Control protocol option Modem Connection Control that allows the Precidia unit to appear as a Hayes compatible modem to your s...

Page 10: ...hen network conges tion results in collisions Collisions are resolved by the Ether net protocol and do not necessarily indicate data loss Lamp flashes to indicate this activity TRANSMIT Illuminates wh...

Page 11: ...ecessed CONFIGURE button for several seconds to activate local configuration through the COM port ETHERNET Accepts RJ 45 connector for direct connection to 10BaseT Ethernet network NOTE If connecting...

Page 12: ...configuration and one 1 RS 422 serial cable with an RJ 45 connector For RS 485 connections one 1 null modem serial cable for configuration and one 1 RS 485 serial cable with an RJ 45 connector IMPORTA...

Page 13: ...ngs depending on your set up and the protocol you are using Ethernet Settings IP Address Subnet Mask Gateway These are the addressing information of the unit and the network Leave at zero if using a D...

Page 14: ...1 Before You Start Ether232Plus User Guide 8 Precidia Technologies Inc 02 CML000057...

Page 15: ...THERNET port of the unit 3 Connect the null modem cable to the COM port of the unit 4 Plug the power adapter into a power outlet 5 Connect the null modem cable to one of the COM ports on your PC 6 Fol...

Page 16: ...s stan dard with Windows operating systems or Procomm Plus Symantec For further help on using Hyper Terminal please refer to our Help Guide Working With HyperTer minal at http www precidia com product...

Page 17: ...g the Configuration Screen The left half of the Configuration screen displays the Device Settings menu and the right half of the screen displays the sub menu of the option you select Table 2 1 provide...

Page 18: ...nfigure the local network information before the device is placed on a network so it does not cause a problem with the existing LAN or configure auto matically with a DHCP server 2 Serial Port Configu...

Page 19: ...ll delete your previous configuration and revert all settings to factory default 1 Unplug the power cord from the back of the unit 2 Press and hold the recessed CONFIGURE button and plug the power cor...

Page 20: ...2 Setting up the Ether232Plus Ether232Plus User Guide 14 Precidia Technologies Inc 02 CML000057...

Page 21: ...enu appears on the right side of the Configuration screen as shown below NOTE Remember to save your changes by typing to exit configuration Precidia Ether232Plus Configuration v4 04 00 Device Settings...

Page 22: ...automatically enables DHCP configuration If you are using a DHCP server leave all Ethernet Settings at zero 0 0 0 0 The settings will always appear as zeros in the menu regardless of the values assign...

Page 23: ...rnet from the Device Settings menu 2 Choose Subnet Mask from the Ethernet Settings sub menu You are prompted to enter the subnet mask of the device 3 Type the subnet mask e g 255 255 255 0 at the prom...

Page 24: ...atches this Network Address and the Network Mask it is forwarded to the second gateway address defined below To enter or change the Network Address 1 Choose Ethernet from the Device Settings menu 2 Ch...

Page 25: ...be on the same subnet as the device To enter or change the Gateway 1 Choose Ethernet from the Device Settings menu 2 Choose Gateway under Additional Gateway from the Ethernet Settings sub menu You are...

Page 26: ...3 Configuring the Ethernet Settings Ether232Plus User Guide 20 Precidia Technologies Inc 02 CML000057...

Page 27: ...otocol option first NOTE Remember to save your changes by typing to exit configuration Precidia Ether232Plus Configuration v4 04 00 Device Settings Serial Port Settings 1 Ethernet 0 0 0 0 A Protocol T...

Page 28: ...om the message and sets the following parameters of the serial port baud rate data length parity bits stop bits DTR signal often used to disconnect a call and flow control Once the serial port is set...

Page 29: ...te IP address and Remote Port Telnet Server To create a telnet server select tcp server as the session mode when configuring this protocol The Ether232Plus lis tens on port 23 and the Remote Password...

Page 30: ...1 Any zeroes after the first terminator are ignored Table 4 2 Session Mode Options Menu Item Description tcp tunnel Typical configuration for most applications Use tcp tunnel mode when the Ether232Pl...

Page 31: ...ntrol NOTE To avoid data loss choose hardware flow control if you set the port speed to 19 200 bps or higher udp Similar to tcp tunnel mode use UDP mode when reception acknowledgement of the data pack...

Page 32: ...data as fast as it is received from the Ether232Plus the remote end negates CTS and the Ether232Plus suspends data transfer When the remote end is ready for more data it asserts CTS again When the Eth...

Page 33: ...Port configurations of 9 12 or 13 bits are automatically converted by adding an extra stop bit to 9 bit transfers and dropping stop bits and parity bits if necessary from 12 and 13 bit transfers 4 3 P...

Page 34: ...otocol connection to the status of the network Ethernet Attempts to keep the connection permanently open DTR DSR Control Uses the DTR DSR lines to open and close connections In tcp client mode the Eth...

Page 35: ...re effective to set it yourself If the terminal type is incorrect the full screen telnet applications will not work properly To enter or change the Terminal Type Telnet only 1 Choose Serial Port from...

Page 36: ...the Serial Port Settings sub menu You are prompted to enter the port number on the local system 3 Type the port number at the prompt and press Enter 4 7 Remote IP Remote IP is the IP address of the r...

Page 37: ...s sub menu You are prompted to enter the port number on the remote system 3 Type the remote port number at the prompt and press Enter 4 9 Fallback IP Fallback IP is the IP address of the machine the u...

Page 38: ...avoid using reserved port numbers NOTE If the session mode is set to udp this option is ignored To enter or change the Fallback Port 1 Choose Serial Port from the Device Settings menu Table 4 5 Fallba...

Page 39: ...must be specified in their ASCII decimal form For example Carriage Return is entered as 13 The most common terminators are listed in Table 4 6 NOTE To use zero null as a terminator you must set it as...

Page 40: ...s with ETX and has a 2 byte CRC that follows you will want to terminate on 3 with 2 tail bytes However if you get an ACK you may not want to collect any tail bytes at all so you would terminate on 6 w...

Page 41: ...character delay specifies the maximum elapsed time in milliseconds between received characters before the Ether232Plus forwards the data packet to the destination to a maximum of 60 000 ms This optio...

Page 42: ...Type your preferred packet size and press Enter 4 15 Initial String Transparent Protocol Only Initial String allows you to insert a string of characters that are prepended to the initial data packet a...

Page 43: ...ppears on the right side of the Configuration screen as shown below NOTE Remember to save your changes by typing to exit configuration Precidia Ether232Plus Configuration v4 04 00 Device Settings Secu...

Page 44: ...assword from the Security Settings sub menu You are prompted to enter a console access password with a maximum of 8 charac ters 3 Type your password appears as a series of asterisks and press Enter Vi...

Page 45: ...st of uppercase letters lowercase letters numbers or symbols 1 Choose Security Settings from the Device Settings menu 2 Choose Remote Password from the Security Settings sub menu You are prompted to e...

Page 46: ...d System Log If you enable the Web Server and do not configure Access Userid and Access Password default anyone who knows the IP address of the unit can access the pages through a Web browser NOTE HTT...

Page 47: ...security against unauthorized access to the Precidia unit s dynamic Web pages Setting the Access Password NOTE Passwords are case sensitive and can consist of uppercase letters lowercase letters numbe...

Page 48: ...as shown below 3 Type the letter that corresponds to the desired setting and press Enter 5 7 SNMP Settings Precidia products support SNMPv2c SNMP Simple Network Management Protocol is a protocol for...

Page 49: ...two separate networks IMPORTANT IPsec contains computationally intensive algorithms Enabling IPsec may cause a significant decrease in the speed performance of the Precidia unit If your application ha...

Page 50: ...ot been altered en route from the sender MD5 is described in RFC1321 Choose IPsec Tunnel 1 or IPsec Tunnel 2 from the Security Settings sub menu The Secure IP Association 1 or 2 sub menu appears as sh...

Page 51: ...ynamic IP Address of the unit To enter or change the Secure IP address 1 Choose Secure Address from the Secure IP Association sub menu You are prompted to enter the secure IP address of this device 2...

Page 52: ...dress of the remote device To enter or change the Network Address 1 Choose Network Address from the Secure IP Association sub menu You are prompted to enter the IP address of the secure network 2 Type...

Page 53: ...s a 128 bit number in hex format The Auth Key is configured in two parts of 64 bits each To set or change the Encode Key 1 Choose Encode Pt1 from the Secure IP Association sub menu You are prompted to...

Page 54: ...oose Auth Pt2 from the Secure IP Association sub menu You are prompted to enter bits 65 128 of the authentication key in hex 4 Type the second half of the authentication key 16 characters in hexadecim...

Page 55: ...own below NOTE Remember to save your changes by typing to exit configuration Precidia Ether232Plus Configuration v4 04 00 Device Settings System Settings 1 Ethernet 192 168 1 28 A Unit ID value 00 01...

Page 56: ...ION Do not attempt a Firmware Download without first consult ing the instructions and obtaining the correct firmware file from Pre cidia Improper downloading may render the warranty null and void Use...

Page 57: ...The status information appears an example of which is shown below See Section 7 1 System Status on page 57 for a description of the System Status page 6 5 Dump System Log Dump System Log allows you to...

Page 58: ...eed to use this feature during the normal course of opera tion The self test takes a few minutes to run and the unit is unable to process any information during this time To run Perform Self Test 1 Ch...

Page 59: ...t session without saving any changes to the configuration menu 6 9 SNTP Settings Simple Network Time Protocol SNTP is used to synchronize computer clocks on the Internet Every 5 minutes a request is s...

Page 60: ...f the device 3 Type the unique IP address at the prompt in the format xxx xxx xxx xxx and press Enter 6 9 2 Secondary Server 1 Choose SNTP Settings from the System Settings sub menu 2 Choose Secondary...

Page 61: ...ption 1 Choose System Setting from the Device Settings menu 2 Choose Disable TCP keep alives from the System Settings sub menu You are prompted to choose a Disable TCP keep alives option shown below S...

Page 62: ...6 System Settings Ether232Plus User Guide 56 Precidia Technologies Inc 02 CML000057...

Page 63: ...age 37 Additionally you have the ability to create custom Web pages through which you can remotely control the serial device connected to the Precidia unit Refer to 7 3 Static Web Page for further inf...

Page 64: ...er locally or remotely 2 Choose System Settings from the Device Settings menu Ether232Plus Status Current time is 2004 03 12 20 03 23 System Uptime Up 0 days 0 08 01 Load Average 5sec 0 30sec 0 5min 0...

Page 65: ...4 00 2004 03 05 Port 1 serial transparent tcp server idle Received Transmitted Bytes 0 Bytes 0 Packets 0 Packets 0 Avg BpP 0 Avg BpP 0 Network Routing Local Network Subnet Mask Gateway Iface Pkts I n...

Page 66: ...g This section reveals how the system is handling the data going through the Precidia unit in the same style as the print route command Table 7 2 describes each param eter in the Network Routing secti...

Page 67: ...days 09 07 22 Port 1 Connection was established with 192 168 1 2 2569 00000 days 09 07 37 Port 1 Connection closed by remote host at 192 168 1 2 2569 00000 days 09 07 37 Port 1 Connection closed by u...

Page 68: ...the Ether232Plus Configuration screen either locally or remotely 2 Choose System Settings from the Device Settings menu 3 Choose Dump System Log from the System Settings sub menu Ether232Plus Log Jum...

Page 69: ...sage Ether232Plus Log Deleted The Ether232Plus had its log deleted If present this message will always be the first entry in the log CONSOLE login accepted The unit went into console configu ration mo...

Page 70: ...ion on tcp port pppp The unit will allow incoming TCP connections on port pppp Port n Connection attempt to xxx xxx xxx xxx pppp The unit is contacting the remote server at the IP address and port ind...

Page 71: ...erid pass word protected HTTP pages Internet Explorer may attempt access using old data from previous connections resulting in this error Configuration changes saved restarting system A configuration...

Page 72: ...the unit which does not need renewal DHCP address xxx xxx xxx xxx acquired for xxx seconds DHCP assigned an IP address to the unit for the indicated number of sec onds Before expiration DHCP attempts...

Page 73: ...nother port Check that the port num ber is available for use Change configuration if necessary 10 requested port number is already in use 11 requested address was not valid for operation 12 operation...

Page 74: ...ory for static web page s HTML pages and associated files must be converted to a hex file format for download Refer to the Help Guide Coverting and Downloading Static Web Pages at http www precidia co...

Page 75: ...nsmitted with a block of data in order to detect corruption CSU Channel Service Unit A device that performs protective and diagnostic functions for a telecommunications line CTS Clear To Send A modem...

Page 76: ...en computers DTR Data Terminal Ready A modem signal line pin 4 of DB 9 connectors used for RS 232 hardware flow control It is the counterpart to Data Set Ready DSR Ethernet An industry standard local...

Page 77: ...t Significant Bit Byte Bit zero the bit in a binary number giving the number of ones the last or rightmost bit MD5 Message Digest 5 An algorithm used to verify data integrity through the creation of a...

Page 78: ...ress correspond to the network address and subnet portions of the address The subnet mask has ones in positions cor responding to the network and subnet numbers and zeros in the host number posi tions...

Page 79: ...modem use a specialized null modem serial cable See Specialized Null Modem Serial Cable on page E 1 Some POS terminals may also require this type of cable 3 If you know the IP address of the unit you...

Page 80: ...Appendix B Troubleshooting and Support Ether232Plus User Guide B 2 Precidia Technologies Inc 02 CML000027 Troubleshooting Configuration Access Troubleshooting Flow for Set Up Connection...

Page 81: ...bleshooting Table B 1 Basic Troubleshooting Problem Solution The Configuration screen does not appear when I press the CONFIGURE button 1 Follow the troubleshooting flow diagram on the previous page B...

Page 82: ...net work Ensure the IP Address Subnet Mask and Gateway are correctly configured This can be done manu ally or through a DHCP server The unit is not communicating with the serial device 1 Ensure all ca...

Page 83: ...232Plus Check to confirm the opposite end with the black transformer is plugged into a power outlet Check the power outlet by plugging in a known operational power plug Replace the power adapter with...

Page 84: ...rsts Table B 4 COLLISION Lamp Troubleshooting Lamp Status Standard Troubleshooting Procedure On Collision between data streams has occurred Ensure the Ethernet cable is properly plugged into the Ether...

Page 85: ...from configuration mode Flashing OK data is being trans mitted None Off No data is being trans mitted Ensure the serial cable between the Ether232Plus and the serial device is properly connected Was...

Page 86: ...ou within one business day General information User Guides and Help Guides available at http www precidia com See Appendix C Specifications and Warranty for warranty information Off Unit may be incorr...

Page 87: ...nterface Ethernet IEEE 802 3 10baseT Ethernet connector RJ 45 Ethernet speed 10 Mbps Indicators Power on Ethernet link collision transmit COM transmit sta tus Protocols Services ARP ICMP UDP TCP IP HT...

Page 88: ...ees Warranty exclusions This warranty shall not apply to appearance or any accessory items including but not limited to cables This warranty shall in addition not apply to damages due to handling tran...

Page 89: ...Address and Subnet Mask or automatically with DHCP the Gateway address if necessary or automatically with DHCP the Remote Password Refer to the User Guide for more information on configuring these set...

Page 90: ...e Telnet in the Port field 5 Click Connect You are prompted to enter your password in the Telnet window 6 Type the Remote Password you created during local configuration and press Enter The Configurat...

Page 91: ...r the Precidia device is acting as a Hayes compatible modem modem connection control you will need a null modem cable with the wiring below This cable may also be required for certain POS terminals Th...

Page 92: ...pply Ether232Plus User Guide E 2 Precidia Technologies Inc 02 CML000027 RS 485 Serial Cable If you are connecting an RS 485 serial device to the Ether232Plus you will need a 2 wire cable with an RJ 45...

Page 93: ...logies Inc E 3 Connectors COM Port Pinout DB 9 Pin Signal Type 1 Data Carrier Detect DCD In 2 Receive Data RD In 3 Transmit Data TD Out 4 Data Terminal Ready DTR Out 5 Signal Ground GND Power 6 Data S...

Page 94: ...also used for RS 485 connections using an RS 485 cable with an RJ 45 connector as illustrated on page E 2 Pin Signal Type 1 Transmit positive TX Out 2 Transmit negative TX Out 3 Receive positive RX I...

Page 95: ...forming to the specifications below Customers in other parts of the world should obtain a power supply that meets these requirements Output Voltage 9 VDC 500 mA Polarity Center Pin Negative or Positiv...

Page 96: ...Appendix E Pinouts and Power Supply Ether232Plus User Guide E 6 Precidia Technologies Inc 02 CML000027...

Reviews: