FSLIMPRO05 - 10 - 15 - 20 - 25
ENGLISH
ISFSLIMPRO_10_12_uk.doc
4.
OPERATING PRINCIPLE
The FSLIMPRO infra-red beam barrier comprises a MASTER and a SLAVE card with beam 1 on-board, and an
additional beam made up of a pair of TX transmitter and RX receiver probes.
Each beam consists of a pair of signals, one outgoing the other incoming. The former is transmitted by the
MASTER card to the Slave card that upon correctly receiving the signal relays it back to the MASTER card, thus
practically acting like an “electronic” mirror.
The barrier is capable of managing up to four pairs of beams (8 beams overall). Single beam expansions are
available on request (use code FSLIMPLUS when ordering).
5 INSTALLING FSLIMPRO
WARNING : ACCORDING TO BARRIERS INSTALLATION LOCATION, THE SUN MAY CREATE
DISRUPTIONS AND TRIGGER FALSE-ALARMS.
5.1 Mounting and wiring up
1.
If necessary, cut the black anodised sections and the polycarbonate to the desired lengths and sizes.
2.
Identify points where to drill the holes for fastening the sections to the wall, for wire routing, and for inserting
the tear-proof tamper if necessary.
3.
Use a Ø 4 bit to drill the fastening holes, a Ø 10.5 one for the wire routing hole, and a Ø 7.5 one for the tear-
proof tamper hole.
4.
Position the TX Transmitter and RX Receiver probes inside the sections as desired and fasten into place by
means of the self-threading screws provided (see Figure 1).
5.
Strip the multi-pole power cable and the tamper and alarm contacts.
6.
Insert the wire routing bush hole onto the section and route in the cable (see Figure 2).
7.
Insert the rubber plug at the top end of the section (see Figure 3).
8.
Fit the sponge pad inside the plastic plug so as to cover the condensate drain hole. Insert the plastic plug
inside the section (see Figure 5).
9.
Insert the rubber tear-proof tamper actuators into the appropriate holes and fit the clips onto the anti-
opening tampers (see Figure 2).
10. Secure the sections to the wall by means of the fastening screws and relevant O rings.
11. Fit the flat probe cable into the section and fasten down with the clip provided (see Figure 1).
12. Wire up power and alarm connections as shown below and power the barrier with 12 Vdc. The barrier is
now fully operative with all due default settings.
MASTER
SLAVE
TX
TX
RX
RX
TX
RX
TX
RX
BEAM 1
BEAM 2