1. INTRODUCTION
FSLIMPRO is especially designed and built for quick and easy installation. Installation is truly made easy
and wiring up is minimised (only the power supply cable and alarm contacts require wiring up) thanks to the
electronics incorporated in the sections and to the fact that there are no synchronism signals to be
transmitted by wire.
Sections are available in a number of lengths (from 1 to 2.5 m) so as to perfectly satisfy all protection
requirements. Fastening screws with appropriate O rings and specially shaped plugs guarantee perfect
section anchoring and seal, and durable outdoor installations.
Probe positioning to the desired height inside the FSLIMPRO so as to optimise barrier security as required is
easy and reliable thanks to the specially shaped aluminium sections and the fool-proof probe fastening
system.
2. MAIN FEATURES
•
Sections in aluminium
•
Top end plug in rubber and bottom end one in ABS with sponge pad protected aperture in the bottom for
air circulation against the risk of misting over because of condensate build-up inside the column and of
insects getting in and damaging the photocells.
•
Cover in polycarbonate.
•
Screws and O rings for secure wall anchoring.
•
Equipped with four pairs of trans receiver probes.
•
Possibility of using up to 8 pairs of probes.
•
Sliding on appropriate guide inside the Transmitter and Receiver probes and fastening by means of
screws.
•
A tear-proof and anti-opening tamper on each column.
•
Complete with cable routing bush hole for 6mm external diameter cable.
•
Incorporated photocell amplifier with the following technical features:
multiplex and synchronised system;
management of up to 8 beams with 2 by 2 selection;
1 N.O./N.C exchange relay output.
•
Easy installation and probe alignment thanks to four levels of intensity of the infra-red beams.
•
Enabling of beams used by means of the four contact “BEAMS” Dip-Switch.
•
Beam status indicator LED:
on = beam broken off or disabled
off = beam aligned or not broken off
•
Operating mode selection via “FUNCTION” (1 and 2 ) Dip-Switch, as described in the following table:
Dip 1 Dip 2
Alarm activation
OFF
OFF
Beam broken off for at least 0.1seconds
ON
OFF
At least two adjacent beams broken off for 200msec,
or two non-adjacent ones for 500msec
OFF
ON
At least two adjacent beams broken off for 200msec,
or one beam for 1second
ON
ON
One beam broken off for 1 second
3.
TECHNICAL SPECIFICATIONS
Power supply
12Vdc
Power consumption
Electric current requirement
Max. 1.5 W
Max 50mA (4 pairs of enabled beams)
I.R. wave length
950 nm
Operating range
10 metres indoors / 6 metres outdoors
Relay outputs (clean exchange contact)
N.O. / N.C
Relay response time
Minimum 100ms, maximum 1second
Reset time
0.5 seconds
Working temperature range
-20
°
C to +55
°
C