FSLIMPRO05 - 10 - 15 - 20 - 25
ENGLISH
ISFSLIMPRO_10_12_uk.doc
2.
Select desired alarm mode with Master “FUNCTION” 1 and 2 Dip Switches.
Dip 1 Dip 2
Alarm activation
OFF
OFF
One beam broken off for at least 0.1seconds
ON
OFF
At least due adjacent beams broken off for 200msec,
or two non-adjacent beams for 500msec
OFF
ON
At least two adjacent beams broken off for 200msec,
or one beam for 1second.
ON
ON
A beam broken off for at least 1 second
3.
Select beam intensity with Master “RANGE” 3 and 4 Dip Switches and Slave “RANGE” 1 and 2 Dip
Switches depending on distance profiles and environmental conditions. MASTER and SLAVE normally
require the same setting.
Master
Dip 3
Dip 4
Max. in-/outdoor distance profiles
ON
ON
10/6 metres
ON
OFF
7/4 metres
OFF
ON
4/2 metres
OFF
OFF
2/1 metres
Slave
Dip 1
Dip 2
Max. in-/outdoor distance profiles
ON
ON
10/6 metres
ON
OFF
7/4 metres
OFF
ON
4/2 metres
OFF
OFF
2/1 metres
ON
OFF
FUNCTION
Alarm
Activation
Mode
1 2 3 4
RANGE
OFF
ON
RANGE
Beam Range
1 2
ON
OFF
FUNCTION
1 2 3 4
Beam
Range
RANGE