ASSEMBLY

 

PREREQUISITES

 

The wallbox may only be installed by a trained electrician. 

Before installation the device must be thoroughly checked for 

damage. The wallbox is only suitable for vertical installation. 

The wallbox may be installed indoor or in protected outdoor areas, such as under canopies. 

The ambient temperature at the installation site must be in the range of -20°C to +40°C. 

The wallbox must be mounted away from easily flammable parts. 

Sufficient ventilation must be ensured during operation. 

The installation location must be chosen so that the connected charging cables cannot come into contact with water. 

To prevent the ingress of water check the proper fit of the cover and the tight fit of the cable glands after installation. 

 

WALL MOUNTING

 

1.

 

The enclosed mounting plates (left/right) must be mounted on the back of the wallbox using four self-tapping screws 

each. Make sure that the bevelled tabs are oriented towards the centre of the housing (see figure 1). 

2.

 

Use the enclosed drilling template to transfer the drilling distances for wall mounting to the wall. 

3.

 

Drill holes in the wall. 

4.

 

Insert four dowels (not included in the scope of delivery) according to the wall condition. 

5.

 

Screw the two lower screws into the dowels and place the wallbox on the screws using the screw holes. 

6.

 

Screw the upper screws into the wall plugs, align the wallbox and finally fasten it using the four screws. 

Tabs 

Figure 1 Arrangement of the mounting plates

 

 
 

 

The next step is the electrical connection of the wallbox. 

Summary of Contents for ALPHA XT NRG1002

Page 1: ...ALPHA XT NRG1002 MANUAL Status March 2021...

Page 2: ...LL MOUNTING 6 ELECTRICAL CONNECTION 7 CONNECTION TO THE MAINS 7 SETTING THE MAXIMUM CURRENT 7 INITIAL COMMISSIONING 8 OPERATION 9 LED DISPLAY 9 LEARNING OF RFID CARDS 9 ERASING RFID CARDS 9 UNLOCKING...

Page 3: ...ut into operation for the first time by a trained electrician The electrical connection must be made in accordance with nationally applicable standards and other national and international regulations...

Page 4: ...hicle must be parked at a suitable distance from the charging station to ensure that the charging cable can be plugged in without tension Avoid direct sunlight Do not open an outdoor charging station...

Page 5: ...sembled Operating instructions Drilling template Fixingmaterial consistingof 1x mounting bracket left 1x mountingbracket right 8x self tapping screws for mounting brackets 2 RFID cards additional card...

Page 6: ...ng location Mounting type Ambienttemperature Altitude Relative humidity Dimensions mm W x H x D Material Weight kg Optionally available 230 1 phase 400 3 phase 50 30 6 10 13 16 20 24 or 32 16 IP 65 I...

Page 7: ...k the proper fit of the cover and the tight fit of the cable glands after installation WALL MOUNTING 1 The enclosed mounting plates left right must be mounted on the back of the wallbox using four sel...

Page 8: ...correctly SETTING THE MAXIMUM CURRENT It should be noted that the charging speed is essentially dependent on two factors 1 The maximum power output of the wallbox 2 Maximum charging power of the elect...

Page 9: ...W 11 0kW 11 0kW 11 0kW Check that the jumper is correctly seated before commissioning No settings are necessary to divide the charging current between two vehicles The charging current is regulated by...

Page 10: ...not known all RFID cards successfully deleted 3 seconds white RFID card has been tuned in The LED indicator lights also show the preset current consumption every time the box is restarted LEARNING OF...

Page 11: ...harging points to which no vehicle is connected are blocked by the wallbox after 30 seconds As long as the connected vehicle is waiting or charging the connected charging point remains unlocked After...

Page 12: ...ts automatically Within 2 seconds the box signals the preselected setting by white flashing of the LEDs 10 flashes signal a presetting of 10 amps INTERFACE RS 485 The RS 485 interface communicates wit...

Page 13: ...ermitted The wallbox must not be cleaned with a water jet or high pressure cleaner ENVIRONMENT Dispose of the packaging material via the collection containers for paper and plastics provided for your...

Page 14: ...Afterrepairor cleaning the wallboxcan beconnected tothe mains If the fault has been rectified the box is ready for operation The vehicle suddenly charges with a lower chargingcurrentor briefly interru...

Reviews: