background image

 

ELECTRICAL CONNECTION

 

The supply line of the wallbox must be disconnected from the power supply during installation work. 

CONNECTION TO THE MAINS

 

The supply line must be correctly fused. 

1.

 

Pull the supply cable into the box. 

2.

 

Connect the supply cable as shown in figure 2 and then relieve the strain and seal it using the cable gland. 

CONNECTING 

TERMINALS 

 

FEED POINTS FOR SUPPLY CHAIN 

(up to 16mm²) 

 

 

Figure 1 Connection position of the supply line

 

 

 

Check the electrical connection and voltages with the help of a meter. 

Also make sure that neutral (blue) and earth (PE, yellow/green) are connected correctly. 

 

SETTING THE MAXIMUM CURRENT

 

It should be noted that the charging speed is essentially dependent on two factors: 

1.

 

The maximum power output of the wallbox 

2.

 

Maximum charging power of the electric vehicle. 

Preferably the wallbox should be connected with three phases. 
Before commissioning, the maximum current that the wallbox draws via the supply line must be set using the enclosed jumper 
on the control board. 
When setting the maximum current, it must not be higher than the fuse or the cable cross-section and the length of the supply 
line allow. 

 

The setting is made by plugging the jumper into the corresponding position on the control unit. The slots on the control unit can 
be found by the inscription "I max". The assignment of the slots is shown in the following table: 

RCD SWITCH 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ALPHA XT NRG1002

Page 1: ...ALPHA XT NRG1002 MANUAL Status March 2021...

Page 2: ...LL MOUNTING 6 ELECTRICAL CONNECTION 7 CONNECTION TO THE MAINS 7 SETTING THE MAXIMUM CURRENT 7 INITIAL COMMISSIONING 8 OPERATION 9 LED DISPLAY 9 LEARNING OF RFID CARDS 9 ERASING RFID CARDS 9 UNLOCKING...

Page 3: ...ut into operation for the first time by a trained electrician The electrical connection must be made in accordance with nationally applicable standards and other national and international regulations...

Page 4: ...hicle must be parked at a suitable distance from the charging station to ensure that the charging cable can be plugged in without tension Avoid direct sunlight Do not open an outdoor charging station...

Page 5: ...sembled Operating instructions Drilling template Fixingmaterial consistingof 1x mounting bracket left 1x mountingbracket right 8x self tapping screws for mounting brackets 2 RFID cards additional card...

Page 6: ...ng location Mounting type Ambienttemperature Altitude Relative humidity Dimensions mm W x H x D Material Weight kg Optionally available 230 1 phase 400 3 phase 50 30 6 10 13 16 20 24 or 32 16 IP 65 I...

Page 7: ...k the proper fit of the cover and the tight fit of the cable glands after installation WALL MOUNTING 1 The enclosed mounting plates left right must be mounted on the back of the wallbox using four sel...

Page 8: ...correctly SETTING THE MAXIMUM CURRENT It should be noted that the charging speed is essentially dependent on two factors 1 The maximum power output of the wallbox 2 Maximum charging power of the elect...

Page 9: ...W 11 0kW 11 0kW 11 0kW Check that the jumper is correctly seated before commissioning No settings are necessary to divide the charging current between two vehicles The charging current is regulated by...

Page 10: ...not known all RFID cards successfully deleted 3 seconds white RFID card has been tuned in The LED indicator lights also show the preset current consumption every time the box is restarted LEARNING OF...

Page 11: ...harging points to which no vehicle is connected are blocked by the wallbox after 30 seconds As long as the connected vehicle is waiting or charging the connected charging point remains unlocked After...

Page 12: ...ts automatically Within 2 seconds the box signals the preselected setting by white flashing of the LEDs 10 flashes signal a presetting of 10 amps INTERFACE RS 485 The RS 485 interface communicates wit...

Page 13: ...ermitted The wallbox must not be cleaned with a water jet or high pressure cleaner ENVIRONMENT Dispose of the packaging material via the collection containers for paper and plastics provided for your...

Page 14: ...Afterrepairor cleaning the wallboxcan beconnected tothe mains If the fault has been rectified the box is ready for operation The vehicle suddenly charges with a lower chargingcurrentor briefly interru...

Reviews: