8
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the button CMD (9x) to enter the function;
4. Press and release the REC button;
5. CMD button to decrement value, or REC to increase value.
6. Finally, remove PROG jumper.
NOTICE:
If the function is disabled (level 0), the setting of the trimpot RAMP is used to both
sides of opening and closing.
Otherwise, different level of 0, the distance from the ramp closing will be defined
by trimpot RAMP and the function setting 9 (Adjust the opening ramp) will be for
the opening cycle.
route perMitteD
Maximum time allowed for the opening/closing cycle of the gate. Setting the A/F
maximum time:
values:
0 = 30 sec
1 = 40 sec
2 = 50 sec
3 = 60 secs
4 = 80 secs
5 = 100 secs
6 = 120 secs
7 = 150 secs
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the button CMD (10x);
4. Press and release the REC button;
5. CMD button to decrement value, or REC to increase value.
6. Finally, remove PROG jumper.