triMpot setting tHe Delay tiMe

If closing is adjusted at minimum, the delay time will be canceled and the engine 

will be triggered simultaneously; otherwise, the RETA engine will first be activated 

and after time set by the trimpot RETF engine will be connected. If opening is set 

to the minimum, delay time will be canceled and the engine will be triggered 

simultaneously; otherwise, the RETF engine will be turned on first and after time of 

1.0 sec the RETA engine will turn on and if the sensor is released FCF_RETF.

Minimum time = 1.0 sec.

Maximum time = 7.0 sec.

iMpotants tips

SETTING WITH RAMP DECELERATION AND SOFT STOP:

After mechanical installation, with the limit switch properly installed and gates in 

the middle of the route.

1.  Adjust trimpot strength 1/2 turn. 

2.  Insert jumper A/S (semiautomatic) 

3.  Trimpot torque at a minimum. 

4.  Trimpot ramp close to 1/4 turn to a minimum. 

5.  Trimpot RET 1/4 turn to a minimum. 

6.  Delete route as item CLEARNING ROUTE.  

7.  After command (CMD) the gates will open by the limit switch without ramp 

and after another command will close by the limit switch without ramp 

and note that for each gate to complete the cycle the SN LED will flash fast, 

indicating that the route A / F was memorized for each leaf. 

8.  After this initial memorizing process, the gates will get in ramp mode to soft stop.

Summary of Contents for DUPLA 5T

Page 1: ...DUPLA 5T BOARD WARNING Do not use the equipment without reading the instruction manual Technical Manual...

Page 2: ...t Module Lock Module Traffic Light Module Deceleration ramp Automatic Memory of route A F IMPORTANT First programming after installation or setting new type of transmitter This procedure will detele a...

Page 3: ...GHT TIME SIN 6 REVERS L BY COMMAND 7 MAGNETIC LOCK RAMP 8 OPENING ADJUSTMENT OPENING 9 MAXIMUM TIME COURSE A F 10 NOMINAL ENGINE TIME 11 LIMIT SWITCH REVERSE BRAKE 12 ELIMINATE BRAKE INERTIA 13 ELIMIN...

Page 4: ...ns 1 Gate must be stopped 2 Close jumper PROG 3 Press and release the CMD button 3x 4 Press and release the REC button to enter the function 5 REC button to erase the memory of the transmitters or CMD...

Page 5: ...and release the CMD button 4x 4 Press and release the REC button to enter the function 5 CMD button to decrement value or REC button to increase value or remove jumper PROG Cancel function Signage SN...

Page 6: ...he gate or when it is stopped the relay module will be on or swinging When the central finalizes the closing cycle the relay module will shut down Values 0 on module 1 Time oscillation 0 050 the 2nd 2...

Page 7: ...e closing distance to trigger the magnetic lock Values 10 adjustment levels 0 2 9 20 Operation 1 Gate must be stopped 2 Close jumper PROG 3 Press and release the CMD 8x button to enter the function 4...

Page 8: ...rent level of 0 the distance from the ramp closing will be defined by trimpot RAMP and the function setting 9 Adjust the opening ramp will be for the opening cycle ROUTE PERMITTED Maximum time allowed...

Page 9: ...REVERSAL BRAKE This feature will ensure that the gate will be completely closed to find the closing limit switch Operation 1 Gate must be stopped 2 Close jumper PROG 3 Press and release the CMD 12x b...

Page 10: ...d 2 Close jumper PROG 3 Press and release the button CMD 14x to enter the function 4 Press and release the REC button 5 CMD button to decrement value or REC button to increase value 6 Finally remove P...

Page 11: ...quired during the gate movement Scale trimpot 20 levels Clockwise lower strength Anticlockwise increase strength TRIMPOT ADJUSTMENT OF PULSATING TORQUE This setting will slow the gate when your route...

Page 12: ...ec IMPOTANTS TIPS SETTING WITH RAMP DECELERATION AND SOFT STOP After mechanical installation with the limit switch properly installed and gates in the middle of the route 1 Adjust trimpot strength 1 2...

Page 13: ...INE STARTING CAPACITOR ENGINE STARTING CAPACITOR BLACK RED RED BLACK YELLOW BLACK RED RED BLACK YELLOW BUTTONHOLE RELAY MODULE RELAY MODULE RELAY MODULE INCORPORATED RP RECEPTOR 433 92 MHZ SEPARATED R...

Page 14: ...MOTOPPAR IND STRIA E COM RCIO DE AUTOMATIZADORES LTDA Av Dr Labieno da Costa Machado 3526 Distrito Industrial CEP 17400 000 Gar a SP Brasil www ppa com br 55 14 3407 1000...

Reviews: