12
triMpot setting tHe Delay tiMe
If closing is adjusted at minimum, the delay time will be canceled and the engine
will be triggered simultaneously; otherwise, the RETA engine will first be activated
and after time set by the trimpot RETF engine will be connected. If opening is set
to the minimum, delay time will be canceled and the engine will be triggered
simultaneously; otherwise, the RETF engine will be turned on first and after time of
1.0 sec the RETA engine will turn on and if the sensor is released FCF_RETF.
Minimum time = 1.0 sec.
Maximum time = 7.0 sec.
iMpotants tips
SETTING WITH RAMP DECELERATION AND SOFT STOP:
After mechanical installation, with the limit switch properly installed and gates in
the middle of the route.
1. Adjust trimpot strength 1/2 turn.
2. Insert jumper A/S (semiautomatic)
3. Trimpot torque at a minimum.
4. Trimpot ramp close to 1/4 turn to a minimum.
5. Trimpot RET 1/4 turn to a minimum.
6. Delete route as item CLEARNING ROUTE.
7. After command (CMD) the gates will open by the limit switch without ramp
and after another command will close by the limit switch without ramp
and note that for each gate to complete the cycle the SN LED will flash fast,
indicating that the route A / F was memorized for each leaf.
8. After this initial memorizing process, the gates will get in ramp mode to soft stop.