garage ligHt tiMe (lg)
During opening or closing cycle the gate open or stopped, the relay module will
be connected.
When the central finalize the closing cycle, the relay module will be turned off after
scheduled time.
Values:
0 = Minimum time 1.0 second
1 = 15.0 Split time the 2nd
2 = 30.0 Split time the 2nd
...
17 = Maximum time the 2nd 255.0
Operations:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the CMD button (4x);
4. Press and release the REC button to enter the function;
5. CMD button to decrement value, or REC to increase value or remove
jumper PROG (Cancel function).
Signage SN led:
Flash 1x = Releasing CMD and / or GRV + button (command accepted).
Flash fast for 1 second = Releasing button CMD (command denied to minimum values).
Light for 1 second = Releasing GRV + button (command denied for maximum values).
BraKe
It is triggered to turn off the motor command, or to find the limit switch analog
sensors.
Values:
0 = on brake.
Time 1 = 0.150 the 2nd
2 = 0.300 time the 2nd
...
17 = Time oscillation 2.55 seconds