7
reVersal By CoMManD
Command permission buttonhole or transmitter operate during the gate closing
path for reversal.
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the button CMD (7x);
4. Press and release the REC button to enter the function;
5. REC to enable rollback command, or CMD button to disable the
rollback command.
6. Finally, remove PROG jumper.
route tHe DriVe MagnetiC loCK
Adjust the closing distance to trigger the magnetic lock.
Values:
10 adjustment levels.
0 = 2%.
...
9 = 20%.
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the CMD (8x) button to enter the function;
4. Press and release the REC button;
5. CMD button to decrement value, or REC to increase value.
6. Finally, remove PROG jumper.
opening aDJusting in tHe raMp
It allows you to individually adjust the distance of the opening ramp to get into
pulsating torque to reduce gate speed.
Values:
17 adjustment levels.
0 = disabled function.
1 = 5% of the total route.
2 = 10% of the total route.
3 = 15% of the total route.
...
16 = 80% of the total route.