Part 4: Loading batteries
ELECTRICAL SAFETY
Ensure the Powervault G200 is completely
isolated from the mains supply.
i
Connect the battery cables to the batteries prior to
the loading the batteries into the unit. Connect the
RED cable to the positive terminal and the BLACK
cable to the negative terminal using a socket wrench.
ii
Place the battery terminal covers over the terminals.
iii
Remove screws from top tray to allow for 2nd row
of batteries to slide in place. Keep the screws in a
safe place for re-installation.
Option A:
Loading Lead Acid batteries
Lead Acid Unit
+
-
+
-
Power Connection
To Powervault
Cables Supplied as Part of Accessory Box
Connect Red to positive and Black to Negative
Note: 2 Batteries must be connected on any shelf
Connection Detail 2 Batteries Per Shelf
Cables supplied as part of accessory box
connect RED to positive and BLACK to negative
Power connection
to Powervault
Note: Two batteries should be plugged into the
socket on each level. The unit will not work if
only one battery is plugged into a socket.
FIGURE 10