I. Installation Requirements 

 

 

1.  Where to install 

 
The Power Inverter should be installed in a location that meets the following requirements: 
  

 

   

 

Dry 

– 

Do not expose the Inverter to high levels of moisture, rain, snow, spray or bilge fluids. Make sure the 

Inverter is not exposed to salt water vapour. 

 

Temperature –

 Ambient air temperature should be between 0°Cand 40°

C. 

Do not expose the Inverter to heat 

sources or direct sunlight. 

 

Safety – 

Do not install in a battery compartment or other areas where flammable fumes may exist, such as fuel 

storage or engine compartments. 

 

Ventilation – 

Allow at least 25mm of clearance around the inverter for airflow. Ensure the ventilation openings on 

the sides and bottom of the unit are not obstructed. The installation site should not be susceptible to temperatures 
in excess of 50°C. 

 

Dust-free – 

Do not install the inverter in an environment where there is dust, wood particles or other 

filings/shavings present. These can pull into the unit blocking the cooling fans.  

 

Close to battery/batteries – 

Avoid excessive cable lengths 

(Mount the inverter between one and two meters 

from the batteries)

 but do not install the inverter over or in the same compartment as batteries. Use the 

recommended wire lengths and sizes. Do not mount the inverter where it will be exposed to the gases produced 
by the battery or battery bank. These gases are very corrosive and prolonged exposure will damage the inverter.

 

 

Wall-mount 

 

Inspection and operation of the Inverter is easier if the unit is mounted at a convenient height and 

the DC cables hang naturally out of the way. 

  
2.   Safety Grounding  
 

To prevent electrical shock, 

DO NOT

 operate the Inverter without connecting it to an appropriate ground. 

 

 
3.   230V Models  

 

There is no connection made inside the Inverter from either of the line conductors (line or neutral) to the earth ground. 
 

 

 

 

 

 

 

Please read these instructions carefully before commencing installation. 

 

Installation should be performed by competent qualified installer as dangerous voltages can be present. Complete 
the following steps in the order shown: 
 

4. Mounting 
 

 

Unpack the Inverter from the shipping container and inspect the unit for any obvious transit damage. Report any 
concerns immediately to your supplier. 

 

Mount the Inverter to a suitable surface, paying close attention to the mounting requirements previously 
mentioned in this manual. 

 

5. AC 

Wiring 

 

Important:

 to satisfy warranty requirements and conditions, a qualified electrician must perform all AC wiring. 

WARNING! 

 

Operation of the inverter without a proper ground connection may result in an 
electrical safety hazard.   

Summary of Contents for MI-5180

Page 1: ...ine Wave DC to AC Power Inverter User Manual MI 5180 Distributed By Electus Distribution Pty Ltd 320 Victoria Road Rydalmere NSW 2116 Australia Tel 1300 738 555 Fax 1300 738 500 www electusdistribution com au ...

Page 2: ...ctions 3 E Front View Main Functions 4 F Rear View Main Functions 4 G Pre Installation Information 5 H Electrical Requirements 5 I Installation Requirements 6 J Connection and Testing 7 K Operation 8 L Green Power Adjustment 9 M Trouble Shooting 9 N Maintenance 11 O Specifications 12 ...

Page 3: ...ywhere State of Art auto load sense Simplified system design Pure sine wave at 50Hz Remote control unit Lowest installation cost Green Power function Extremely efficient Reliable Easily mounted No noise D Safety Instructions 1 General Safety Instructions Do not expose the Inverter to high levels of moisture rain snow spray bilge dust sources of heat or sunlight To reduce risk of hazard do not cove...

Page 4: ... a spark or flame in vicinity of batteries or an engine Do not drop a metal tool on the battery The resulting spark or short circuit of the battery may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce short circuit currents high enough to weld a ring or similar metal causing a severe b...

Page 5: ...ck NEG Negative DO NOT extend the DC cable length to the Inverter unless you are prepared to increase the diameter of the cable If this is necessary consult your supplier installer for advice DO NOT connect AC power to the AC output of the Inverter THIS WILL DAMAGE THE INVERTER Between the Inverter and any generator mains supply it is essential you install a double pole break before make changeove...

Page 6: ... Use the recommended wire lengths and sizes Do not mount the inverter where it will be exposed to the gases produced by the battery or battery bank These gases are very corrosive and prolonged exposure will damage the inverter Wall mount Inspection and operation of the Inverter is easier if the unit is mounted at a convenient height and the DC cables hang naturally out of the way 2 Safety Groundin...

Page 7: ...Connection and Testing For a quick connection and performance check please follow these guidelines Note The connection to the Negative NEG terminal of the Inverter should be the last connection made A spark when making this final connection is normal Step 1 Unpack and inspect the Power Inverter for any damage Step 2 Make sure the power switch in the OFF position Step 3 Connect the DC Positive cabl...

Page 8: ...t be used K Operation To operate the Inverter turn it ON using the Power ON OFF switch on the front panel The Inverter is now ready to deliver AC power to your appliances loads If you are operating several appliances loads from the Inverter turn them ON separately after the Inverter has been switched ON This will ensure that the Inverter does not have to deliver the starting currents for all loads...

Page 9: ...t Some loads such as TVs must be turned OFF at the power point as they can still represent a small load to the Inverter Using a small screwdriver adjust the black plastic trim pot located to the right of the over voltage indicator and to the left of the power switch Turning this control fully clockwise will override the Standby circuit and keep the Inverter ON all the time This could be used if yo...

Page 10: ...erter has shut down because the protection circuits have sensed the DC input voltage is lower than that recommended for safe operation If this occurs Charge the battery Check the battery voltage at the terminals of the Inverter is within specification If the input voltage drops too low you may need to increase the capacity of your batteries Also check DC cables and terminations 6 Over Voltage Shut...

Page 11: ...mp cloth to prevent accumulation of dust and dirt At the same time check and tighten all cable terminations on the DC input terminals WARNING There are no user serviceable parts inside Only qualified personnel should carry out maintenance or service the device Do not open or disassemble the Inverter Attempting to service the unit yourself may result in a risk of electrical shock or fire ...

Page 12: ...Range 10VDC to 16VDC Green Power Recovery Time 1 Second LED Status Indication Power ON OFF RUN GREEN POWER Standby Under Over Voltage Shutdown Over Temperature Shutdown and Over Load Shutdown Protection Input Under Over Voltage Over Temp Reverse Input Polarity Fuse Over Load Short Circuit Shutdown Restarts Soft Start Remote Control ON OFF Switching with 3M cable Operation Temperature Range 0 C 40 ...

Reviews: