III. ELECTRICAL HOOK-UP

WARNING

BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION,
BE SURE THE SWITCH AT MAIN BREAKER PANEL IS “OFF” TO AVOID

ANY DANGER OF ELECTRICAL SHOCK.

This unit must have its own independent circuits. 

(For PS19T use 2 SETS of UL listed 2 conductor

and ground core copper wire cable of the appropriate size protected by 2 separate and independent
correctly rated Double Pole breakers. See Figure 2).  (For PS28T use 3 SETS of UL listed 2 
conductor and ground core copper wire cable of the appropriate size protected by 3 separate and 
Independent correctly rated Double Pole breakers. See Figure 3).

Applies for 208, 220 or 240 V.

Wire entry into the unit must be made through the hole provided in the flange on the bottom.

The “live” wires should be connected to the slots in the terminal block marked L1 and L2. The
ground lead must be connected to the slot marked GND. GROUND MUST BE BROUGHT TO

THE “GROUND” AT THE CIRCUIT BREAKER PANEL.

DANGER

FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY.

* Units rated of 240 V can operate at 220 V or 208V with reduced output. 

The output will vary in accordance with the following ratios:

208 volts   220 volts    240 volts   

.75            .84             1.0

output ratio

volts

M O D E L   T Y P E

O U T P U T   /  k W

V O L T A G E   /  V

A M P E R A G E

P S 1 9 T

1 9

*2 4 0

2   X   4 0

P S 2 8 T

2 8

*2 4 0

3   X   4 0

ON

ON

OF

F

OF

F

ON

OF

F

ON

OF

F

3 Separate and independent

correctly rated Double pole

breakers (240/208 Volts)

Figure 3

7

*

Circuit Breaker Panel

ON

ON

OF

F

OF

F

ON

ON

OF

F

OF

F

ON

ON

OF

F

OF

F

2 Separate and independent

correctly rated Double pole

breakers (240/208 Volts

)

Figure 2

Circuit Breaker Panel

Summary of Contents for PS19T

Page 1: ...DILY INJURY AND OR PROPERTY DAMAGE READ ALSO THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN...

Page 2: ...THE PS28T MUST HAVE THREE DEDICATED INDEPENDENT CIRCUITS USING CORRECTLY RATED WIRES AND CIRCUIT BREAKERS WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SE...

Page 3: ...al G L1 L2 L1 L2 To 2 Independent circuit breakers MINIMUM 8 CLEARANCE ABOVE UNIT POWER INDICATOR LIGHTS TEMPERATURE ADJUSTMENT CONTROL TERMINAL BLOCK ELECTRICAL HOOK UP 240 208 V Outlet isolating val...

Page 4: ...ABOVE UNIT Outlet isolating valve ball valve leave open just enough to obtain adequate flow of hot water 4 serial L1 L2 L1 L2 L1 L2 TERMINAL BLOCK ELECTRICAL HOOK UP 240 208 V TEMPERATURE ADJUSTMENT...

Page 5: ...mum of 8 above the unit for easy replacement of the element 5 The heater should be fixed to the wall using screws in the four mounting holes at each corner of the backplate NOTE The heater should be i...

Page 6: ...ow switch 3 Install isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes 4 When all plumbing is complete fully check the s...

Page 7: ...ided in the flange on the bottom The live wires should be connected to the slots in the terminal block marked L1 and L2 The ground lead must be connected to the slot marked GND GROUND MUST BE BROUGHT...

Page 8: ...ile carrying out the procedures outlined below OPERATING UNIT AND SETTING WATER TEMPERATURE IV COMMISSIONING YOUR HEATER a Flow enough hot water to activate unit The indicator light on the black flow...

Page 9: ...When the indicator light is on continuously the unit is emitting full power When it is pulsing the unit is modulating the power to achieve the temperature set by means of the temperature adjustment s...

Page 10: ...Solution 5 ELEMENT BURNED OUT TURN OFF THE MAIN BREAKER Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element The resistance readi...

Page 11: ...9 5 KW 240 V REPLACEMENT HEATER CORE ASSEMBLY PS19T REPLACEMENT PARTS DIAGRAM CEC 340 Mad River Park Waitsfield VT 05673 800 642 3111 To 2 Independent circuit breakers 11 EX 65 INLET FILTER SCREEN BLA...

Page 12: ...TS DIAGRAM BLACK FLOW CONTROL BOARD EX 101 240 CLEAR THERMOSTATIC CIRCUIT BOARD EX 100 240 CEC 340 Mad River Park Waitsfield VT 05673 800 642 3111 4 01 12 To 3 Independent circuit breakers serial L1 L...

Reviews: