II.  PLUMBING HOOK-UP

1) The unit is supplied with compression fittings (Figure 1), USE THESE. DO NOT USE

TAPERED THREADED PIPE FITTINGS AND DO NOT SOLDER TO THE INLET OR
OUTLET. DO NOT USE ANY PIPE DOPE OR TEFLON TAPE WITH THESE
COMPRESSION FITTINGS.

2) Take care to ensure that the pipes are correctly aligned with the inlet and outlet bosses 

in order to avoid excessive stress on the heater body molding.
NOTE: When soldering pipe joints remove heater from the wall. Serious damage can occur

if any soldering is done while pipes are connected to the heater.

Run water through the supply pipe to remove all debris from the pipe before
connecting the heater. Failure to do so could cause damage to the flow switch.

3) Install isolating valves (full flow ball valve type) on both inlet and outlet pipes. This allows unit

to be isolated for maintenance purposes. 

4) When all plumbing is complete, fully check the system for water leaks at all the plumbing 

connections. If a leak is present take corrective action. If the leak is at a compression fitting, 
slowly tighten the compression nut until it stops. Fully open both inlet and outlet BALL VALVES.
Run all the hot water outlets fed by this heater one at a time, for a minute or two, until the water
flow  is continuous, free from “gulping” and from all visible air pockets.            

HOT OUTLET

COMPRESSION

FITTING 

DO NOT SOLDER

COLD INLET

COMPRESSION

FITTING 

DO NOT SOLDER

NOTE:

ALL MOUNTING AND PLUMBING MUST BE COMPLETE BEFORE YOU

PROCEED WITH ELECTRICAL HOOK-UP.

TEST THE INSTALLATION FOR LEAKS BEFORE CONNECTING THE

ELECTRICAL SUPPLY.         

Figure 1

6

COLD INLET
FILTER SCREEN

Summary of Contents for PS19T

Page 1: ...DILY INJURY AND OR PROPERTY DAMAGE READ ALSO THE ENCLOSED WARRANTY CARD WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN...

Page 2: ...THE PS28T MUST HAVE THREE DEDICATED INDEPENDENT CIRCUITS USING CORRECTLY RATED WIRES AND CIRCUIT BREAKERS WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE DEATH SE...

Page 3: ...al G L1 L2 L1 L2 To 2 Independent circuit breakers MINIMUM 8 CLEARANCE ABOVE UNIT POWER INDICATOR LIGHTS TEMPERATURE ADJUSTMENT CONTROL TERMINAL BLOCK ELECTRICAL HOOK UP 240 208 V Outlet isolating val...

Page 4: ...ABOVE UNIT Outlet isolating valve ball valve leave open just enough to obtain adequate flow of hot water 4 serial L1 L2 L1 L2 L1 L2 TERMINAL BLOCK ELECTRICAL HOOK UP 240 208 V TEMPERATURE ADJUSTMENT...

Page 5: ...mum of 8 above the unit for easy replacement of the element 5 The heater should be fixed to the wall using screws in the four mounting holes at each corner of the backplate NOTE The heater should be i...

Page 6: ...ow switch 3 Install isolating valves full flow ball valve type on both inlet and outlet pipes This allows unit to be isolated for maintenance purposes 4 When all plumbing is complete fully check the s...

Page 7: ...ided in the flange on the bottom The live wires should be connected to the slots in the terminal block marked L1 and L2 The ground lead must be connected to the slot marked GND GROUND MUST BE BROUGHT...

Page 8: ...ile carrying out the procedures outlined below OPERATING UNIT AND SETTING WATER TEMPERATURE IV COMMISSIONING YOUR HEATER a Flow enough hot water to activate unit The indicator light on the black flow...

Page 9: ...When the indicator light is on continuously the unit is emitting full power When it is pulsing the unit is modulating the power to achieve the temperature set by means of the temperature adjustment s...

Page 10: ...Solution 5 ELEMENT BURNED OUT TURN OFF THE MAIN BREAKER Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element The resistance readi...

Page 11: ...9 5 KW 240 V REPLACEMENT HEATER CORE ASSEMBLY PS19T REPLACEMENT PARTS DIAGRAM CEC 340 Mad River Park Waitsfield VT 05673 800 642 3111 To 2 Independent circuit breakers 11 EX 65 INLET FILTER SCREEN BLA...

Page 12: ...TS DIAGRAM BLACK FLOW CONTROL BOARD EX 101 240 CLEAR THERMOSTATIC CIRCUIT BOARD EX 100 240 CEC 340 Mad River Park Waitsfield VT 05673 800 642 3111 4 01 12 To 3 Independent circuit breakers serial L1 L...

Reviews: