RED00202(R2) MANUAL

Safety regulations: Please read these instructions completely before using the equipment. Keep these 
instructions on to hand. The device may only be operated by trained specialist staff. 

Installation: 

1) The device is designed for devices and systems
that meet the standard requirements for hazardous
voltages, power, and fire prevention.
2.) Installation and service only by trained persons.
The AC power must be switched off. The work is to be
labelled; accidental reconnection of the system must
be prevented.
3.) Opening the device, its modification, loosening
bolts, or operation outside the specified herein
specification or in an unsuitable environment, has the
immediate loss of warranty to follow. We disclaim any
responsibility for any resulting damage to persons or
things.

Warning:

Non-compliance these warnings can result in fire 
and serious injury or death.

 

1. Allow neat and professional cabling.
2. Never open nor try to repair the unit. Inside
are dangerous voltages that can cause electrical
shock hazard.
3. Avoid metal pieces or other conductive
material to fall into the item
4. Do not operate the device in damp or wet
conditions
5. Do not operate the unit under EX-conditions

All parameters base on 15 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated. 

[email protected]

www.powersolve.co.uk

020321

Summary of Contents for RED00202A

Page 1: ...protected Monitoring relay floating Low voltage drop Screw terminals 16mm2 EN62368 1 Schottky barrier decoupling diodes Efficiency 97 Adjustable drop out voltage detection 20 C 70 C ambient temperature IP20 metal housing Models Voltage RED00202A R2 0 28Vdc RED02020B R2 36 60Vdc RED00202C R2 90 125Vdc sales powersolve co uk www powersolve co uk 020321 ...

Page 2: ...wer Good Relay Change over contact Relay contact load 48Vdc 500mA max Relay contact separation Protective electrical insulation 60Vdc Cooling Natural convection Ambient temperature 20 C 70 C Storage temperature 40 C 85 C Environment Humidity 95 non condensing 25 C climate class 3k3 pollution degree 2 ROHS 2011 65 EU EU 2015 863 REACH EG No 1907 2006 EMI EN55032 class B EN61000 6 3 EMS EN61000 6 2 ...

Page 3: ...p between DC input and DC output is between 500mV and 700mV see table Technical Data Current voltage graph Voltage control specification The change over contact of the control relay is at the left position when the input voltage V1in and V2in operate between Vu and Vo The LED of each input lights green The relay contact changes to the right position when the input voltages are either smaller Vu or...

Page 4: ...ED00202 Stable metal aluminium housing IP20 To allow adequate convection a free air space of 50mm top bottom and 10mm sidewalls is required and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the RED One can use the DIN Rail installation equipped standard with our patented 35mm DIN Rail bracket according to EN60715 It is easy to mount dismount ...

Page 5: ... H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 20 12mm H6 0 20 SW 14mm 10 0mm H10 0 12 12mm H10 0 22 EB 15mm The length of ferrules is to be chosen depending on the rated voltage The outside diameter of the plastic collar should not be larger than the pitch P Ordering Information Ordering Codes Product Code Volt Power Information Article Number RED00202A R2 0 28Vdc 1000W below 12Vdc is the DC OK relay ...

Page 6: ...ng bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things Warning Non compliance these warnings can result in fire and serious injury or death 1 Allow neat and professional cabling 2 Never open nor try to repair the unit Inside are dangero...

Reviews: