LED chart
13 : 1.Interface board LED chart
For a comprehensive control on system status refer
to the ArmoníaPlus metering interface (ref.
Color
Label
Signal
Lighting
RED
PROTECT
Signal protection
active
SOLID ON
No pressure sensor
connected
BLINKING
RED
LIMIT
Limiter active
SOLID ON
GREEN
SIGNAL Input signal present SOLID ON
GREEN
E.SAVE
Energy save mode
active
SOLID ON
YELLOW
TEMP
Thermal protection
active
SOLID ON
GREEN
READY
No faults, system
fully operating
SOLID ON
GREEN
ON
System on
SOLID ON
13 : 2.SIMM board LED chart
Color
Code
Signal
Lighting
GREEN
D2
+5V
DC
SOLID ON
RED
D4
signal clip
ON
GREEN
D5
ready
SOLID ON
RED
D8
protection active
ON
The architecture of Powersoft’s amplifiers encompass
several protection mechanisms triggered by harmful signal
and temperature. Protection systems and triggers are
independently implemented in the power supply section
(power supply protection) and the amplifier section (amplifier
protections). (ref.
Chapter 15 : 3.Advanced parameters
12 : 1.Thermal Protections and Fan Control
Fan starts to run as soon as the amp module measures
a temperature greater than 35°*, the fan control keeps fan
at maximum speed for the first 2s, then its speed will be
controlled according to operating temperature.
When the amp module reaches 45°**, or when the
module reaches the 500 W threshold, the fan starts to run
at maximum speed.
At 60
o
the temperature Led will turn solid on, at 80
o
the
unit will shutdown.
The temperature of the Amplifier section is monitored
and replicated on the 34 poles interface connector
according to the TEMPON table:
12
FIGURE 12: M-Drive interface plate.
13 | M-Drive | User guide