30. Handle R Assy. 3
F-COVER SW UNIT-N
(* CONNECTOR: GREEN)
TRIGGER SW UNIT C5
(* CONNECTOR: RED)
F-COVER SW UNIT-N
(* CONNECTOR: BLUE)
Beware of the direction of the
Electrode Block.
* Positive side downward
ELECTRODE BLOCK ASSY. (* CONNECTOR: WHITE)
2-D BARCODE LABEL
The harness should be located inside the wall.
CONTROL ASSY.
1. Write the data to the Control Assy. (Connect to the red, green and white connectors.)
2. Stick the 2-D Barcode to the Handle R.
3. Connect the connectors the Solenoid Valve Assy. (Blue), F-cover SW Unit-N (Green), Trigger SW
Unit C5 (Red) and Electrode Block Assy. (White) to the control assy.
Connect the connectors of the same color to each other.
* Erroneous connection may damage the erroneously connected part.
* Beware of the direction of the Electrode Block Assy.
ASSEMBLY PROCEDURE
−
29
−