PowerQuick Powered Ascender
(3)
PQ500-1 1-Sep-15
Load limiter: Prevents lifting of load in excess of 900 lbs (409 kg).
Auto-braking in hands-off position provides for emergency stop.
Static Load/Stationary holding capacity: 1,100 lbs (500kg)
Dynamic load capacity: 2,500 lbs (1,136 kg)
Forward reverse power control
Palm Interlock must be engaged to start unit
Low voltage sensor detects low battery voltage and shuts unit down. PQ 500 level is 26 VDC,
No pinch points
No sharp edges, points, etc., capable of puncturing or cutting the skin
Accessible surface temperature do not exceed 65° C
Rotating parts protection
No shock hazard
Use restrictions
Not to be used after shock load of in excess of 1,200 lbs (544kg).
Not to be used after drop greater than 4 ft (1.2meters) onto hard surface
(Must undergo inspection and recertification after these events)
Environmental conditions
Moisture: May be used in wet weather. However; do not immerse this product in water, for example, a
lake, swimming pool or water puddle. May result in serious personal injury and damage to the machine.
No negative affect from corrosive environments, e.g. salt water or spray. Should be cleaned after use in
these environments
Dust, sand, dirt, mud etc: .The ascender can be used in oily, or dirty conditions without affecting the
performance. However; for rope safety, keep ascender clean of heavy debris. Inspect and clean rope
prior to each use and periodically during use.
Power Supply
NiMH Rechargeable Battery: 36vdc, 30 amp, 360 amp-minutes discharge to 25 vdc.
Climbing Time: 500 to 600 feet (152-182m) per charge.
Battery Pack Weight: 14 lbs.
Operating Temperature Range: 32˚ F to 113˚F (0˚ C to +45˚ C). When working in extreme cold keep
the batteries warm (store in the cab of your truck) when not in use. Once in use internal heat is
generated. An insulated battery sleeve is also available.
Designed to withstand 4-ft (1.2meters) drop on hard surface.
Battery life: approximately 800 charge/discharge cycles (temperatures extremes can affect battery life)
Battery is protected with an internal fuse that will disable the battery in event of a short circuit. The
standard battery uses a blade type 40 amp fuse.
The battery cable is 6 foot long with a threaded connector on either end. The cable connectors are such
that it is impossible to connect the cable backwards.
Charger
Use to charge PowerQuick NiMH battery packs only
Input: 115/230VAC 60/50 Hz 1.8/1.0A
Output 36VDC/2.6A Continuous
1.
Personal Safety
Do not operate if under the age of 18. Do not operate unless YOU HAVE BEEN TRAINED by a certified
trainer. Dangerous in the hands of untrained users.
For information on PowerQuick, Inc. approved trainers contact your distributor.
Stay alert, watch what you are doing and use common sense when operating the Power Quick
Ascender. Do not use while tired or under the influence of drugs, alcohol, or medications. A moment of
inattention while operating may result in serious personal injury.
Figure 1
Battery
Charger
Summary of Contents for PQ 500-1
Page 46: ......
Page 48: ...NOTES...