background image

 

Operating Instructions and Parts Manual 

5HP Mobile Cyclone Dust Collector 

Model PM2205 

 

 

Powermatic 

427 New Sanford Road

  

 

LaVergne, Tennessee 37086 

Document No. M-1792205HK

 

Ph.: 800-274-6848 

Edition 1  12/2020 

www.powermatic.com Copyright © 2020 Powermatic 

This .pdf document is bookmarked

Summary of Contents for 1792205HK

Page 1: ...l 5HP Mobile Cyclone Dust Collector Model PM2205 Powermatic 427 New Sanford Road LaVergne Tennessee 37086 Document No M 1792205HK Ph 800 274 6848 Edition 1 12 2020 www powermatic com Copyright 2020 Powermatic This pdf document is bookmarked ...

Page 2: ...tments or maintenance with the machine unplugged from the power source 13 Remove adjusting keys and wrenches Form a habit of checking to see that keys and adjusting wrenches are removed from the machine before turning it on 14 Keep safety guards in place at all times when the machine is in use If removed for maintenance purposes use extreme caution and replace the guards immediately after maintena...

Page 3: ...xtension cord is in good condition When using an extension cord use one heavy enough to carry the current your product will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating Sect 6 2 Table 2 shows correct size to use depending upon cord length and nameplate ampere rating If in doubt use the next heavier gauge The smaller the gauge number the heavi...

Page 4: ... 12 7 3 Remote controller 12 7 4 Dust hose connection 13 7 5 Filter auto clean 13 7 6 Negative pressure gauge 13 8 0 User maintenance 14 8 1 Thermal overload reset 14 8 2 Cleaning and bag inspection 14 8 3 Motor inspection 14 8 4 Additional servicing 14 9 0 Consumable parts replacement 14 10 0 Troubleshooting PM2205 Cyclone Dust Collector 15 10 1 Electrical and motor problems PM2205 15 10 2 Perfor...

Page 5: ... manual is not intended to be an exhaustive guide to dust removal strategies installation of shop duct work or the use of optional dust collection accessories Additional knowledge may be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments about this product please contact your local supplier ...

Page 6: ...nge up to 50 ft 15m RC transmitter battery 2 x AA 1 5V Timer setting 2 4 6 8 hours Capacities Inlet diameter 8 in 203 2 mm Inlet adaptors number of 3 Inlet adaptors diameter of 4 in 100 mm Air Flow with filters 3 1708 CFM 48 4 m3 min Air Velocity 3 4 464 FPM 24 8 m s Static pressure loss WC 3 2 4 inH2O 60 mmH2O Maximum static pressure loss WC 3 9 8 inH2O 248 mmH2O Impeller Diameter 16 6 in 422 mm ...

Page 7: ...5 lb 211 kg Shipping weight 560 lb 254 kg Box 2 HEPA filter only Net weight 30 8 lb 14 kg Shipping weight 52 9 lb 24 kg 1 Subject to local national electrical codes Recommendation based upon dedicated circuit 2 The specified values are emission levels and are not necessarily to be seen as safe operating levels As workplace conditions vary this information is intended to allow the user to make a be...

Page 8: ...e gauge A 1 Base B 1 Upper drum C 1 Lower drum D 1 Drum lid E 1 Inlet adaptor F 1 Connecting frame G 1 Right stand panel with wiring box H 1 Left stand panel I 1 Hose J 2 Hose 2in K 2 Hose clamps L 1 Cone clamp M 1 Canister bag clamp N 1 Drum handle O 1 Reducing cone P 1 Quick lever Q 2 Fixed casters Ø3 x 1 1 4 R 2 Swivel casters Ø3 x 1 1 4 S 4 Drum casters T 1 PE bag large for drum U 1 Drum clamp...

Page 9: ...screws HP2 Semi tighten screws 3 Install support frame G to left panel and position right panel H Semi tighten all screws 4 Install angle supports E1 with button head screws and washers HP2 3 Semi tighten Half of angle support should protrude upward 5 Assemble handles Y and fully tighten Figure 5 3 Use hoist or forklift with hooks through the eyebolts near the motor to raise housing assembly Lifti...

Page 10: ...15 Assemble cone P to housing with clamp M See Figure 5 8 Position cone so that flanges face forward and are parallel to stand Tighten screw on clamp Figure 5 8 16 The upper drum is nested within the lower drum Remove clamp and lift out upper drum 17 Assemble upper drum C Figure 5 9 to lower drum D and secure with drum clamp V by tightening screw V1 18 Install handle O with screws HP4 Handle shoul...

Page 11: ... dedicated minimum 20 amp circuit with circuit breaker or fuse If connected to a circuit protected by fuse use time delay fuse marked D Local codes take precedence over recommen dations Keep in mind that a circuit being used by other machines tools lights heaters etc at the same time will add to the electrical load A dedicated circuit to the dust collector will offer best results since dust collec...

Page 12: ... If the bulb is bad there will be no indication Always check before use Do not rely that no light means no power to the machine Always check for power first Failure to comply may cause serious injury Refer to Figure 16 Start A Press the green start switch When power is connected to the machine the green light is always on regardless of whether the collector is running or not Stop B Press the red s...

Page 13: ...ize your installation and obtain maximum performance with dust hoods hoses clamps fittings and blast gates 7 5 Filter auto clean Canister filter cleaning is automatic When the dust collector is shut off the cleaning baffles will rotate one direction for 5 seconds then the opposite direction for 5 seconds The auto clean feature can be turned on or off using the toggle switch on the side of the cont...

Page 14: ...ped allow machine to cool down for several minutes Then press breaker reset button C Figure 7 1 and restart dust collector 8 2 Cleaning and bag inspection Empty or replace canister and drum collection bags when full 8 3 Motor inspection Make frequent inspections of motor fan and blow out with low pressure air hose or vacuum any accumulation of foreign material to maintain normal motor ventilation ...

Page 15: ...es Short circuit in motor or loose connections Inspect all connections on motor for loose or shorted terminals or worn insulation Incorrect fuse or circuit breaker in power line Install correct fuse or circuit breaker at power source Motor overheats Motor overloaded Reduce load on motor Air circulation through motor is restricted Clean motor fan to restore normal air circulation Motor stalls resul...

Page 16: ... collector closer to dust source and use shorter hose Excess dust or large chips backing up into canister filter Collection drum not sealed properly Inspect drum for leaks make sure lid is tight Canister collection bag full Empty bag Table 5 11 0 Replacement Parts Replacement parts are listed on the following pages To order parts or reach our service department call 1 800 274 6848 Monday through F...

Page 17: ...17 11 1 1 PM2205 Cyclone Dust Collector Exploded View ...

Page 18: ...tton Screw 5 16 18 x 3 4 63 19 TS 081C022 Pan HD Phillips Machine Screw 10 24 x 3 8 2 20 PM2200 019 Reducing Motor 15W 230V 1 21 JBTS10MJS 620 Pan Head Screw M4 x 60 4 22 PM2200 021B Reducing Motor Cord 1 23 PM2205 023 Control Box Assembly 23 1 thru 23 5 1 23 1 PM2205 023 1 Control Box Back Cover 1 23 2 JCDC2 21 4 Remote Control Transmitter 1 23 3 PM2200 031CB Circuit Board 1 23 4 PM2205 023 4 Mag...

Page 19: ...ton Screw 1 4 20 x 5 8 2 73 1 PM2200 095 Washer 1 4 x18 2 74 PM2205 074 Support Frame 1 75 PM2205 075 Base 1 76 JCDC3 33 Swivel Caster 3 2 77 JCDC3 33 1 Swivel Caster w Brake 3 2 78 PM2200 098 Toothed Lock Washer M5 2 79 717531 Drum Collection Bag pkg of 5 980 x 1200 mm 1 80 PM2200 057 Upper Collection Drum 1 81 JCDC1 5 42 Handle 1 82 JCDC1 5 44 Rubber Pad 1 83 JCDC1 5 45 PC Plate 1 84 PM2200 056 ...

Page 20: ...20 12 0 Electrical Connections for PM2205 Cyclone DC ...

Page 21: ...f a product requires further inspection the Technical Service representative will explain and assist with any additional action needed Powermatic has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the Powermatic website More Information Powermatic is constantly adding...

Page 22: ...22 This page intentionally left blank ...

Page 23: ...23 This page intentionally left blank ...

Page 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...