11
23. Roll drum beneath cone and work hose on to
drum lid. Secure with hose clamp (L).
24. Install quick lever (Q) to flanges of cone with
button head screws (HP5, see inset). Then
connect bottom of handle to drum lid with hex
nut on top and lock nut underneath.
25. Push quick connectors (A1) into the 2-inch
hoses, tighten with hose clamps, and place
connectors onto ports at back of drum (B1).
Figure 5-10
26. Apply 3/4Wx50L inch foam tape (FT3/4, Figure
5-11) to lower groove of canister filter, just
above the lip.
27. Install canister collection bag (C1) beneath
canister filter and secure with bag clamp (N).
28. The dust collector is now assembled and ready
for operation.
Figure 5-11
6.0
Electrical connections
All electrical connections must
be done by a qualified electrician in compliance
with all local codes and ordinances. Failure to
comply may result in serious injury.
The PM2205 Dust Collector is rated at single-phase,
230-volt power only.
A power cable must be supplied by the user,
inserted through the lower strain relief, and properly
connected inside the machine’s junction box. A
proper UL/CSA listed plug may be used, or the
machine may be “hardwired” to a circuit panel.
Confirm that power available at the machine’s
location matches that for which the machine is
wired. It is recommended that the dust collector be
connected to a dedicated minimum 20 amp circuit
with circuit breaker or fuse. If connected to a circuit
protected by fuse, use time delay fuse marked “D”.
Local codes take precedence over recommen-
dations.
Keep in mind that a circuit being used by other
machines, tools, lights, heaters, etc. at the same
time will add to the electrical load. A dedicated
circuit to the dust collector will offer best results
since dust collectors are generally used while other
tools are running.
Before connecting to power source, be sure switch
is in
off
position.
6.1
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should
malfunction or breakdown, grounding provides a
path of least resistance for electric current to reduce
the risk of electric shock.
If a plug is used, it must be inserted into an
appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
Permanently connected tools: This tool should be
connected to a grounded metal permanent wiring
system; or to a system having an equipment-
grounding conductor. Make sure a disconnect is
available for the operator. During hard-wiring of the
machine, make sure the fuses have been removed
or the breakers have been tripped in the circuit to
which the band saw will be connected. ALWAYS
FOLLOW PROPER LOCK-OUT, TAG-OUT
PROCEDURES.
Improper connection of the
equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified
electrician or service person if you are in doubt
as to whether the outlet is properly grounded.
Summary of Contents for 1792205HK
Page 17: ...17 11 1 1 PM2205 Cyclone Dust Collector Exploded View ...
Page 20: ...20 12 0 Electrical Connections for PM2205 Cyclone DC ...
Page 22: ...22 This page intentionally left blank ...
Page 23: ...23 This page intentionally left blank ...
Page 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...