301 cc Yamaha OHV engine

*

Low oil sensor

*

6.5 gallon plastic fuel tank

*

Receptacles on control panel

*

Receptacle dust covers

*

Portability kit

GROUND FAULT CIRCUIT INTERRUPTER (GFCI) 
PROTECTION

Some jobsites and local codes may require GFCI 

protection for personnel before operation of your generator.  If
your generator is not already equipped with a GFCI receptacle,
GFCI In-line cord sets may be purchased from your local 
electrical supply store or home builder appliance store.

These cord sets are available in various plug and 

amperage configurations. 

(Make sure your generator is

properly Grounded.)

NOTE: Total power drawn from all receptacles must not
exceed the nameplate ratings.

A.

120 V, 20 Ampere Duplex Receptacle

20 amps of current may be drawn from either of the duplex

receptacles.  However, total power drawn must be kept within
nameplate ratings. These receptacles may be used along with
the twistlock receptacle provided the generator is not
overloaded.

B.

120/240 V, 30 Ampere Twistlock Receptacle

Maximum full load current may be drawn from the 120/240 

volt receptacle, provided it is the only receptacle used.  Total
current must be limited to the nameplate rating.  If the 120/240
volt receptacle is used along with the 120 volt receptacle, the
total load drawn must not exceed the nameplate ratings.

C.

Circuit Protectors

The receptacles are protected by an AC circuit protector.  If

the generator is overloaded or an external short circuit occurs,
the circuit protector will trip.  If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit protector to trip, reduce the load. 

NOTE:

Continuous tripping of the circuit protector may cause
damage to generator or equipment.  

The circuit protector

may be reset by pushing the button of the protector.

D.

Engine On/Off Switch

E.

Oil Warning Light

F.

Receptacle Dust Covers

Your generator is supplied with a 25 foot 12 GA SJTW 

4-conductor 105ºC power cord set.  This cord is equipped with
an L14-30P twistlock Plug, on one end, which will plug directly
into the mating twistlock receptacle on the control panel of your
generator.  The opposite end comes equipped with a special 4
circuit connector comprised of four 5-20R receptacles.   These
may be used to power individual loads.  

NOTE: For 120 volt

use only.  Make sure the loads do not exceed the 20 amp
rating of the Power Cord Set.

Circuit breaker protection is

provided for on the control panel of your generator.

You will notice that the 4-circuit connector is color coded.

When several loads are powered at the same time, it is best to
keep equal loads supplied to each separately colored half, if
possible.  Each half of the connector is capable of sustaining 20
amps of current provided your generator is capable of
supplying 4800 watts of power.  Check nameplate ratings for
total wattage capability of the generator. 

2

English

CONTROL PANEL

MAJOR GENERATOR FEATURES

CORD SET

TYPICAL CORD CONFIGURATIONS

F

Summary of Contents for PM0675700.04

Page 1: ...GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO PM0675700 04 Insert Additif Adici n Thank you for selecting a Powermate Generator The Powermate generator has been made to supply reliable portable ele...

Page 2: ...overloaded or an external short circuit occurs the circuit protector will trip If this occurs disconnect all electrical loads and try to determine the cause of the problem before attempting to use the...

Page 3: ...to the customer these charges must be borne by the customer If a separate operator s manual and engine warranty from the engine manufacturer is included with this product only that warranty will apply...

Page 4: ...ne et essayer de d terminer la cause du probl me avant d essayer de le r utiliser Si le protecteur de circuit saute en raison d une surcharge r duire la charge REMARQUE Le groupe lectrog ne ou les ap...

Page 5: ...r par s ou remplac s Ces frais doivent tre assum s par le client Si un manuel s par de l op rateur et la garantie de moteur du fabricant de moteur sont inclus avec ce produit seulement cette garantie...

Page 6: ...tor de circuito Los recept culos se protegen mediante un protector de circuito de CA Si se sobrecarga el generador u ocurre un protector de circuito externo el protector de circuito saltar Si esto ocu...

Page 7: ...as o por el reenv o de los productos reparados o de reemplazo al consumidor estos cargos los deber cubrir el cliente Si un manual separado de operario y garant a de motor del fabricante de motor se in...

Page 8: ...8 PARTS DRAWING SCHEMA DES PI CES DIAGRAMA DE PIEZAS...

Page 9: ...5 amp Protecteur de circuit 25 amp Protector de circuito 25 amp 2 25 0049268 Bolt M8 x 16mm Boulon M8 x 16mm Perno M8 x 16mm 3 26 0065278 Shield heat cran de chaleur Pantalla para el calor 1 27 Note B...

Page 10: ...m dulo 1 60H 0065694 Screw flg M5 x 16mm Vis Tornillo 3 60I 0063290 AVR module La tension automatique r gulatrice El regulador autom tico del voltaje 1 60J 0063313 Bolt M5 x 214 Boulon Perno 2 60K 006...

Page 11: ...TISSEMENT Pour viter toute blessure personnelle ou dommage l quipement l installation et tout entretien devralent tre effectu s par un lectricien qualifi ou un pr pos au service autoris En aucun cas u...

Page 12: ...LLC All rights reserved Powermate is a registered trademark of Pramac America LLC 2010 Pramac America LLC Tous droits r serv s Powermate est une marque d pos e de Pramac America LLC 2010 Pramac Americ...

Reviews: