LEFT HAND/RIGHT HAND CONVERSIONS 

 

1.  Determine the hand of the operator required for this 

installation by referring to the illustration below. 

 

LEFT HAND

RIGHT HAND

 

Note

Operators are wired for Right Hand 

operation at the factory. 
 

 

2. Place the Yellow and Blue wires in the appropriate 

positions, as shown below, for Right Hand or Left Hand 
operation. 

 

Note

: If operator hand is being changed, limits 

MUST

 

be reset. 

 

GREEN

BLUE

YELLOW

GRAY

GREEN

BLUE

YELLOW

GRAY

BACK OF MOTOR,

LEFT HAND MOTOR CONNECTIONS

BACK OF MOTOR,

RIGHT HAND MOTOR CONNECTIONS

 

 

18 

MANUAL OPERATION 

 

 

WARNING: TURN OFF POWER SUPPLY BEFORE   
REMOVING COVER.

 

 

1.  Remove (4) cover mounting screws and lift off top cover.  

 

2. Remove crank pin from storage area in drive frame.  See 

Diagram.  

Note: This will disengage interlock and prevent 

power from returning to the operator during manual 
operation

 

3

.  

Insert crank pin in timing 

pulley as shown in 
diagram. Rotate timing 
pulley with crank pin 
until desired position is 
achieved. 

 

 
 
 
 
 
 
 
 
 
 
 

 

4. To resume powered 
operation, remove crank 
pin from timing pulley and 
replace in storage area on 
drive frame.  

 

 

Note: Be sure drive pin is fully inserted back into drive 
frame in order to activate interlock. 

 

5. Replace cover and secure with (4) mounting screws. 

 

 
6. Turn on supply power to operator.

 

CRANK 

PIN

TIMING

PULLEY

TOP COVER

Summary of Contents for MBG

Page 1: ...Installation of Power Head 14 Installation of Barrier Arm 15 Electrical Connections 15 Left Hand Right Hand Conversions 17 Manual Operation 18 Limit Adjustment Procedure 19 Master Slave Operation 20 C...

Page 2: ...mation provided to help ensure safe system design installation and use WARNING Gate operators are only one part of a TOTAL GATE OPERATING SYSTEM It is the responsibility of purchaser designer and inst...

Page 3: ...ate if the automatic controls do not work Locate the pushbutton or key switch and small warning placard within sight of the gate in a secured area at least 10 feet or more from the gate and fence to k...

Page 4: ...hen LEAVE A COPY OF THIS BROCHURE WITH THE END USER 8 END USER SAFETY WARNINGS Be sure you ve been fully instructed on the sequence of operation for your specific gate system s Keep the gate properly...

Page 5: ...ate any controls without watching the movement of the gate 7 Be sure the gate arm DOES NOT come within 2 feet of any rigid object therefore causing an entrapment situation 10 2 FEET 8 If your gate clo...

Page 6: ...Allow at least 2 feet clearance from rigid objects to gate arm 12 INSTALLATION OF MOUNTING PIPE N o t e T h e r e a r e t w o o p t i o n s f o r t h e i n s t a l l a t i o n o f a m o u n t i n g p...

Page 7: ...EAD 1 Remove exterior cover and install 2 2 U bolts as shown below 2 Install 3 8 flat washers 3 8 lock washers and 3 8 nuts 3 Mount power head on top of pipe by inserting pipe up through large hole in...

Page 8: ...ave installations should have SEPARATE power supply wiring or length of wire runs 16 BLK BLK WHT WHT GRN GND INSIDE UTILITY BOX CONNECT AS SHOWN INCOMING POWER 115V 1 OPERATOR UTILITY BOX should be fi...

Page 9: ...UAL OPERATION WARNING TURN OFF POWER SUPPLY BEFORE REMOVING COVER 1 Remove 4 cover mounting screws and lift off top cover 2 Remove crank pin from storage area in drive frame See Diagram Note This will...

Page 10: ...w 4 Remove crank pin from timing pulley and replace in storage area on drive frame Note Be sure drive pin is fully inserted back into drive frame in order to activate interlock 5 Turn on power then ra...

Page 11: ...TIMER TO CLOSE OPTION The operator is equipped with a timer to close option for use with OPEN ONLY control devices such as a radio control or card key control The AUTO RECLOSE TIMER adjustment screw i...

Page 12: ...the gate if closing 3 The CLOSE LOOP provides a signal to close the gate when a vehicle exits the loop LOOP INSTALLATION 1 Layout the desired loop locations per the diagram The standard size chart at...

Page 13: ...or for available sealants 7 Mount the loop detector in the operator and connect the wire loop 26 8 Connect loop detector to the control board as shown in the following diagrams Note The following diag...

Page 14: ...t Used OR BK WH R GR BR GY TO DRIVEWAY LOOP NOTE TWIST LEADS APPOX 6 TURNS PER FOOT 1 2 3 4 5 6 7 8 9 A B CLOSE LOOP CONNECTION WARNING LOOP DETECTOR MUST BE PROGRAMMED TO ACTIVATE OPERATOR WHEN VEHIC...

Page 15: ...___ ______________________________________________ ______________________________________________ 30 _____________________________________________ Notes ______________________________________________...

Page 16: ...charges incurred in connection with the installation of warranted parts In order to activate this warranty the registration form on opposite page MUST be completed and returned within THIRTY CALENDER...

Reviews: