PowerMaster MBG Installation Manual Download Page 12

 

23 

 
2. Electrically connect sensing system to operator terminal strip as 
shown below. 
 

 

 
 

    
 

 

LOOP DETECTOR SYSTEMS AND INSTALLATION 

 

 
 

8'

4'

4'

4'

4'

Road Surface

Sealant

Loop wires

Min 1"

3/16" To 1/4"

Saw Slot

4'

4'

 

 

8

9

15

FROM EDGE SENSOR OR

PHOTOELECTRIC EYE

 

24 

1. The 

EXIT LOOP

 provides a signal to open the gate when a 

vehicle enters the loop zone. 

 

2. The 

REVERSING LOOP

 protects a vehicle in the loop zone 

from being contacted with the gate by over riding any close 
signal while the gate is open, and by reversing the gate if 
closing. 

 

3. The 

CLOSE LOOP

 provides a signal to close the gate when a 

vehicle exits the loop. 

 
 

 

LOOP INSTALLATION

  

       

 

 

1. 

Layout the desired loop 
locations per the diagram. 

 

The standard size chart at 
right will give an approximate 
length of wire required for 
various loop dimensions and 
number of turns required. 

 

CAUTION: The Loop wires and 
Lead-in wires must be a 
continuous piece of wire 
without splices. Only use wire 
intended for this type of 
application. (Type XHHW 
insulation 16AWG) 

 

NOTE:

 Buried steel from drains or 

other systems may affect 
functioning of the loop system. 
Check with the factory for advice 
on any special installations.   

(1-800-243-4476). 
 
 
 
 
 
 

STANDARD LOOP LAYOUTS 

For 36” High Detection 

Summary of Contents for MBG

Page 1: ...Installation of Power Head 14 Installation of Barrier Arm 15 Electrical Connections 15 Left Hand Right Hand Conversions 17 Manual Operation 18 Limit Adjustment Procedure 19 Master Slave Operation 20 C...

Page 2: ...mation provided to help ensure safe system design installation and use WARNING Gate operators are only one part of a TOTAL GATE OPERATING SYSTEM It is the responsibility of purchaser designer and inst...

Page 3: ...ate if the automatic controls do not work Locate the pushbutton or key switch and small warning placard within sight of the gate in a secured area at least 10 feet or more from the gate and fence to k...

Page 4: ...hen LEAVE A COPY OF THIS BROCHURE WITH THE END USER 8 END USER SAFETY WARNINGS Be sure you ve been fully instructed on the sequence of operation for your specific gate system s Keep the gate properly...

Page 5: ...ate any controls without watching the movement of the gate 7 Be sure the gate arm DOES NOT come within 2 feet of any rigid object therefore causing an entrapment situation 10 2 FEET 8 If your gate clo...

Page 6: ...Allow at least 2 feet clearance from rigid objects to gate arm 12 INSTALLATION OF MOUNTING PIPE N o t e T h e r e a r e t w o o p t i o n s f o r t h e i n s t a l l a t i o n o f a m o u n t i n g p...

Page 7: ...EAD 1 Remove exterior cover and install 2 2 U bolts as shown below 2 Install 3 8 flat washers 3 8 lock washers and 3 8 nuts 3 Mount power head on top of pipe by inserting pipe up through large hole in...

Page 8: ...ave installations should have SEPARATE power supply wiring or length of wire runs 16 BLK BLK WHT WHT GRN GND INSIDE UTILITY BOX CONNECT AS SHOWN INCOMING POWER 115V 1 OPERATOR UTILITY BOX should be fi...

Page 9: ...UAL OPERATION WARNING TURN OFF POWER SUPPLY BEFORE REMOVING COVER 1 Remove 4 cover mounting screws and lift off top cover 2 Remove crank pin from storage area in drive frame See Diagram Note This will...

Page 10: ...w 4 Remove crank pin from timing pulley and replace in storage area on drive frame Note Be sure drive pin is fully inserted back into drive frame in order to activate interlock 5 Turn on power then ra...

Page 11: ...TIMER TO CLOSE OPTION The operator is equipped with a timer to close option for use with OPEN ONLY control devices such as a radio control or card key control The AUTO RECLOSE TIMER adjustment screw i...

Page 12: ...the gate if closing 3 The CLOSE LOOP provides a signal to close the gate when a vehicle exits the loop LOOP INSTALLATION 1 Layout the desired loop locations per the diagram The standard size chart at...

Page 13: ...or for available sealants 7 Mount the loop detector in the operator and connect the wire loop 26 8 Connect loop detector to the control board as shown in the following diagrams Note The following diag...

Page 14: ...t Used OR BK WH R GR BR GY TO DRIVEWAY LOOP NOTE TWIST LEADS APPOX 6 TURNS PER FOOT 1 2 3 4 5 6 7 8 9 A B CLOSE LOOP CONNECTION WARNING LOOP DETECTOR MUST BE PROGRAMMED TO ACTIVATE OPERATOR WHEN VEHIC...

Page 15: ...___ ______________________________________________ ______________________________________________ 30 _____________________________________________ Notes ______________________________________________...

Page 16: ...charges incurred in connection with the installation of warranted parts In order to activate this warranty the registration form on opposite page MUST be completed and returned within THIRTY CALENDER...

Reviews: