INSTALLER SAFETY INSTRUCTIONS
BEFORE INSTALLATION
1. Check to see that the operator is proper for this type, size and class of gate and its
frequency of use. If you are not sure, consult factory.
2. Check to see that there are no structures adjacent to the area, which may pose a risk of
entrapment when gate is opening or closing.
3. You must ensure that the gate has been properly installed and works freely in both
directions. Replace or service any worn or damaged gate hardware prior to installation. A
freely moving gate will require less force to operate and enhance the performance of the
operator as well as the safety devices used within the system.
4. Install the gate operator on the inside of the property and/or fence line.
DO NOT
install
an operator on the public side of the gate.
5. Severe injury or death can result from entrapment by a gate. The operator is supplied
with an obstruction sensing primary entrapment protection system. Additional safety
equipment such as electric edges or photocell sensors must be installed to provide the
required secondary entrapment protection system. For assistance in selecting the correct
type of safety equipment, consult the factory.
6. Review the operation of the unit and become familiar with the manual operation
procedure and safety features of the system.
7. You must install a pushbutton control or key switch to allow for normal operation of the
gate if the automatic controls do not work. Locate the push button or key switch and
small warning placard within sight of the gate in a secured area at least 10 feet or more
from the gate and fence to keep users away from the moving gate and fence.
8. Outdoor or easily accessed gate controls should be of the security type to prohibit
unauthorized use. Please consult your local distributor concerning the types and
specifications of available controls.
DURING INSTALLATION
1. Be aware of all moving parts and avoid close proximity to any pinch points.
2. Disconnect power at the control panel before making any electric service connections.
Connection location for controls and safety equipment can be found on the wiring
diagram, and in this manual.
3. Know how to operate the manual disconnect mechanism.
4. Adjust the open and close force adjustment on the control board, in each direction, to
the minimum force required to operate the gate smoothly.
DO NOT increase the force
adjustment setting to make up for rough spots in gate travel -
FIX THE GATE INSTEAD!
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲