background image

16

FENCE

Drive Chain

Conduit depth�

as required�

by local code

30”

14”

Inground depth

as required �

by local code

Cement Pad

2.  Using 1/2” hardware (not supplied), bolt assembled unit to the pad, being sure to align 

operator parallel to the fence.

NOTE: 

Sprockets must face the fence.

FIGURE 4

Summary of Contents for D-SG

Page 1: ...ULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date Installed Your Dealer INSTALLATION AND OWNER S MANUAL MODEL SG DSG Slide Gate Operator UL 325 and UL 991 Listed 8 14 1 2 15 5 8 22 1...

Page 2: ......

Page 3: ...5 16 Attaching Drive Chain 17 19 Electrical Connections 20 Limit Adjustment 21 22 Left Right Hand Conversion 23 Accessory Connections Loop Detector Systems 24 26 Loop Installation Standard Layout Char...

Page 4: ...tions that can result in serious injury or death Take time to carefully read and follow these precautions and other important information provided to help ensure safe system design installation and us...

Page 5: ...l does not detect the presence of the monitored device the unit will function in constant contact for this direction E g The operator detects there is a monitored device on the C OBS terminal but not...

Page 6: ...family units hotel garages retail store or other building servicing the general public CLASS III INDUSTRIAL LIMITED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system intended for use...

Page 7: ...to eliminate traffic backup Distance from the road size of the gate usage levels and gate cycle speed must be considered to eliminate potential traffic hazards 4 The majority of injuries from slide ga...

Page 8: ...e correct type of safety equipment consult the factory 6 Review the operation of the unit and become familiar with the manual operation procedure and safety features of the system 7 You must install a...

Page 9: ...ogether within sight of the gate opening AFTER INSTALLATION You are responsible for ensuring that the end user understands the basic operations and safety systems of the unit INCLUDING THE MANUAL OPER...

Page 10: ...ack AT ALL TIMES Your automatic gate is not for pedestrian use No one should ever cross the path of the moving gate 3 DO NOT allow children to play near your gate or to operate the gate 4 DO NOT opera...

Page 11: ...te should always be maintained to operate manually as easily as possible to provide maximum protection 11 Check all safety systems at least once per month for the correct force speed and sensitivity G...

Page 12: ...sconnect lever to the left and latch it in place See Figure 1 WARNING NEVER OPERATE THE MANUAL RELEASE WHEN THE GATE IS MOVING FIGURE 1 NEVER ATTEMPT TO OPERATE THE MANUAL RELEASE WHEN THE GATE IS IN...

Page 13: ...or is installed Roller Guards are available from various fence suppliers for refitting of these rollers ORNAMENTAL GRILLE TYPE GATES Injuries occur when people put their arms through the openings in t...

Page 14: ...viewed from inside the fence DO NOT APPLY POWER UNTIL TOLD TO DO SO RISK OF ELECTRICAL SHOCK OR INJURY MAY RESULT WARNING 1 Gate must slide freely to fully opened and fully closed position 2 Gate and...

Page 15: ...equired for optional post mounting 2 places 1 2 mounting hardware 4 places not supplied Install Chain Support Bracket as required 1 2 3 Min Gate Lenth Gate Opening A B 40 2 1 3 Gate Opening Gate Gate...

Page 16: ...equired by local code 30 14 Inground depth as required by local code Cement Pad 2 Using 1 2 hardware not supplied bolt assembled unit to the pad being sure to align operator parallel to the fence NOTE...

Page 17: ...Support Backup Plate Chain Sup port Bracket Drive Chain Gate Extension ATTACHING DRIVE CHAIN 1 Install gate brackets at each end of the gate with U bolts provided Do not fully tighten at this time 2 A...

Page 18: ...necessary to prevent them from being damaged during this procedure FIGURE 6 Disconnect Lever Padlock Option Hole Retaining Bracket To Disconnect Drive Move lever to the left until it latches in retain...

Page 19: ...chain tension Jamb Nut FIGURE 7 Gate Bracket Gate Bracket Drive Chain Set Screw Chain Support Bracket Nut U Bolts Nut PowerMaster 9 Tighten the gate brackets securely and lock in position with the set...

Page 20: ...upply damage will result which is NOT covered by warranty 1 Be sure both the power switches at the source and at the operator are OFF 2 In the diagram below find the supply power that matches your ins...

Page 21: ...s until they are both positioned near the center of the limit shaft 2 With the gate at mid travel depress the pressure plate and set the grooved limit nuts approximately 1 inch from the limit switches...

Page 22: ...is procedure until the Open Limit is set When making fine adjustments turn the limit nut 1 4 to 1 2 turn at a time Reconnect power and test run the gate NOTE Open and Close Limit Switches are reversed...

Page 23: ...slides left to open it is a left hand installation PUBLIC AREA OR STREET RIGHT HAND LEFT HAND PUBLIC AREA OR STREET Following are monitored devices that can be used with the APEX II Controller Device...

Page 24: ...tandard size chart on the following page will give an approximate length of wire required for various loop dimensions and number of turns required NOTE Length of lead in wires must be added to loop le...

Page 25: ...d out in Step 1 according to the diagram below Figure 9 FIGURE 9 STANDARD LOOP LAYOUT FOR APPROX 36 HEIGHT DETECTION LOOP SIZE NUMBER OF TURNS LOOP WIRE LENGTH 4X4 4 64 4X6 4 80 4X8 3 72 4X10 3 84 4X1...

Page 26: ...e into the conduit 6 Fill over the loop wires in the groove with a recommended loop sealant Contact your distributor for available sealants SAFETY DEVICE CONNECTIONS NON CONTACT SENSOR INSTALLATION 1...

Page 27: ...Notes...

Page 28: ...Notes...

Page 29: ...two 2 year period provided that product has been registered A one year warranty applies if product has not been registered If any part is found to be defective during this period new parts will be fur...

Page 30: ...wer net faqs Call us toll free 1 800 243 4476 Email us PMtech VEpower net www facebook com PowerMasterOperators REV 2017 1026 Scan QR Code with your Smart phone to find us on the web WWW VEPOWER NET M...

Reviews: