13
PROBLEM CAUSE
SOLUTION
Compressor won’t start in cold
temperature
Too much back pressure in tank
Discharged battery
Compressor too cold
Using wrong grade oil
Release pressure from unloader by pulling toggle
upwards and start the engine.
Recharge
Move compressor to a warmer location.
Use ISO 1001 30W compressor oil in
temperatures above 30
°
F (-1
°
C) and 10W oil
below 30
°
F (-1
°
C).
Low pressure (75 psi) pressure
relief valve opens
Intake valve to high pressure
cylinder is plugged
Contact authorized service centre.
High pressure (225 psi)
pressure relief valve opens
Unloader/check valve blocked
Clean or replace the unloader.
Water in the crankcase
Condensation
Change oil. Run compressor for longer period
until it is hot, ensuring the discharge valve is
open.
Excessive vibration
Loose pulley
Pump or motor not secured
Foundation or frame inadequate
Compressor feet are not level
Tighten pulley.
Tighten bolts.
Check mounting. Surface should be level and
strong.
Level with shims.
Excessive oil consumption
Defective breather valve
Wrong grade oil
Leaking oil seal
Restricted intake
Check breather valve.
Use correct grade of compressor oil.
Replace oil seal.
Check intake system.
Summary of Contents for 11G-2-30H
Page 6: ...6 Figure 3 Compressor Air System...
Page 17: ...17...
Page 30: ...30 8 PUMP PARTS LIST PUMP 10002222 LP205CT USED ON ITEM 8041212...
Page 31: ...31 PUMP 10002222 LP205CT USED ON ITEM 8041212...
Page 32: ...32 PUMP 10002469 LP335SK USED ON ITEM 8120255...
Page 33: ...33 PUMP 10002469 LP335SK USED ON ITEM 8120255...
Page 34: ...34 PUMP 10001977 LPW6548ALHI USED ON ITEMS 8048530 8077513...
Page 35: ...35 PUMP 10001977 LPW6548ALHI USED ON ITEMS 8048530 8077513...
Page 36: ...36 PUMP 10003075 LPSS7550 USED ON ITEM 8120271...
Page 37: ...37 PUMP 10003075 LPSS7550 USED ON ITEM 8120271...
Page 38: ...38 PUMP 10002335 LPV6546ALHI USED ON ITEM 8057739...
Page 39: ...39 PUMP 10002335 LPV6546ALHI USED ON ITEM 8057739...