2.8 Brake
The SW5X is equipped with a service
brake.
This brake has been constructed as
shoe brake and equally serves as
parking brake.
It is located in the rear wheels and is
actuated via cables.
A special adjustment screw is situa-
ted at the right-hand rear wheel.
Any work at the braking
system has to be executed
by qualified persons in a
qualified workshop only.
2.9 Traction
Drive
Assembly
The SW5X
is equipped with an electric
drive assembly with continuous regula-
tion.
2.10 Hydraulic System
(Lift-Up Disposal)
The hydraulic system comprises a
compact unit (hydraulic pump with
hydraulic tank), the hydraulic hoses
and a hydraulic cylinder.
Hydraulic fluid: Mobiloil DTE 15 M
The named hydraulic fluid has been
filled in the hydraulic system in the
factory.
Filling of hydraulic tank: 0.2 gal. (0.76
litre).
2.11 Battery Systems
Before commencing any
work on the electric system
disconnect the battery plug.
Do not use open flames
when handling batteries and
especially when checking
the battery acid level. Provi-
de for sufficient ventilation
in rooms where batteries
are charged. Spilled
(straight) battery acid must
not get into the sewage
system before having been
neutralised.
Comply with the regulations
imposed by law and obser-
ve local provisions.
Open the hood before char-
ging batteries; explosive ga-
ses may occur during the
charging procedure
2.11.1 Low Discharge Signal
Sender
Battery Charging Status Indicator
Upon turning ON by key switch, bat-
tery charging status is shown by dis-
play of green bars (Fig. 5/1). As the
battery discharges during operation,
the lighting green bars extinguish one
after another showing thus always the
current charge status of battery char-
ge.
Flashing of the last two green bars
indicates that operation will be stop-
ped soon. In order to preclude low
discharge of batteries, the sweeping
units are switched off and riding
speed reduced to 50% if battery is
discharged. The red LED (Fig. 5/4)
than flashes.
Setting Other Battery Types
Have the low discharge sig-
nal sender set to other bat-
tery types by qualified per-
sonnel only and in
approved qualified works-
hops only.
2.11.2 Hourmeter
The operating hours of the machine
appear in the display (Fig. 5/2); the
hourmeter will count only during wor-
king or transport ride; only full hours
are displayed).
Description
Fig. 5
16
Summary of Contents for SW5X
Page 1: ...SW5X Battery Version Model PB40BL PB40BH Instruction Manual...
Page 46: ...46 7 Spare parts...
Page 48: ...48 Driving direction...
Page 50: ...50...
Page 52: ...52...
Page 54: ...54...
Page 56: ...56...
Page 58: ...58...
Page 60: ...60...
Page 62: ...62...
Page 64: ...64...
Page 66: ...66...
Page 68: ...68...
Page 70: ...70...
Page 72: ...72...
Page 74: ...74...
Page 76: ...76...
Page 78: ...78...
Page 80: ...80...
Page 82: ...82...
Page 84: ...84...
Page 86: ...86...
Page 88: ...88...
Page 90: ...90...
Page 92: ...92...
Page 94: ...94...
Page 96: ...96...
Page 98: ...98...
Page 100: ...100...
Page 102: ...102...
Page 104: ...104...
Page 106: ...106...
Page 108: ...108...
Page 112: ......