background image

 

                                                                                             

 

 

P

OWERBOND

 

Art.Nr. 9109

                                                                                                                              3

 

   

 

Dear customer, 
 
The glue gun you purchased will help you to glue parts together more easily and more rapidly. Before using 
the gun please read these instructions thoroughly.

 

Product Description

 

 
Proper Use

 

 
The gun works with hot glue which is dispensed under pressure. Therefore, the glue gun should only be 
used by qualified people. Handling the gun properly will save you unnecessary accident hazards and 
problems. 
 

Personal injury or material damage caused by an improper use of the Hot-Melt Glue Gun shall not be 
the manufacturers but the user’s responsibility.

 

Technical Data 

 

Connection 

 

 

 

230 V / 110 V 

Heating 

capacity   400 

Air control glue 

6 bars 

(only in combination with a pressure controller. A filter must be added)

 

Air consumption max.   

 

100 l/min 

Temperature 

control 

  electronic 

Temperature control range 

 

approx. 50 - 200°C / approx. 120 - 390 °F  

(infinitely variable)

 

Overheat 

protection 

  temperature 

controller 

Heat-up time 

 

 

 

3 - 10 min 

(depending on glue type)

 

Power 

cable 

   approx. 

 

Tank 

capacity 

   330 

ml 

Max. application of glue per min. 

330 ml 

Weight hand gun 

 

 

1400 g 

 
 

Accessories 

 
Foot switch part no. 3517/18 
Stationary equipment part.no. 3618 
Balancer part.no. 3544 
Stand for depositing gun part. no. 3586 / 3587 
Funnel for granular glue part. no. 3624 

 

  Special nozzles upon request. 

Please ask for our accessory nozzle leaflet

Summary of Contents for TR55 LCD

Page 1: ...POWERBOND Art Nr 9109 Operating Instructions For The Powerbond TR55 LCD Total Melt Hot Melt Glue Gun...

Page 2: ...e of Contents Product Description 3 Trouble Shooting 4 General Safety Instructions 5 Start up 7 Operation 9 Additional Information 10 EC Conformity Certificate 11 Exploded Views 12 Spare Parts Legend...

Page 3: ...er s responsibility Technical Data Connection 230 V 110 V Heating capacity 400 W Air control glue 6 bars only in combination with a pressure controller A filter must be added Air consumption max 100 l...

Page 4: ...k controller check temperature replace valve Glue is too fluid or too con sistent temperature too high or too low check temperature Glue leaks out of nozzle sound absorber got stuck clogged nozzle spr...

Page 5: ...ng instructions and in particular the safety instructions Make the information available This operating manual shall be kept on the site of operation It must be ensured that all persons operating the...

Page 6: ...cable When replacing a nozzle liquid glue might leak out Warning Risk of burning Never bring the hot nozzle into contact with the cable When your skin got into contact with hot glue immediately cool...

Page 7: ...chosen temperature is not confirmed within a few seconds by pressing the key 3 the device will use the last chosen temperature While the device is heating up to the chosen temperature the numbers on...

Page 8: ...instrument temperature 60 80 C approx 140 175 F and empty For the replacement you need a SW 13 open end spanner You are advised to wear gloves Prior to exchanging nozzles unplug connecting cable Repla...

Page 9: ...t is fitted to a balancer Never lay gun on its side Open premelting tank only if required Keep hot melt free of dirt and humidity When using the stand remove wire strap General Hints Should the sound...

Page 10: ...malfunctions If you observe the operating instructions the gun does normally not need cleaning The glue remaining in the gun will remelt when it is warmed up and can be used for glueing again The glu...

Page 11: ...e been applied EN 60335 EN 292 EN 60204 HD 400 EN 55014 EN 60555 EN 61000 Design modifications influencing the technical data specified in the operating manual and the in tended use thus meaning a con...

Page 12: ...POWERBOND Art Nr 9109 12...

Page 13: ...9 2696 Membrane SEV 10 2697 90 fitting SEV 11 3130 Lid 12 2800 Disc 13 2801 Screw 14 2819 Sheet 15 2802 Intensification 16 2820 Distance 17 2603 O Ring 40x3 Viton 18 2613 Star grip 19 3665 Lock nut 2...

Page 14: ...POWERBOND Art Nr 9109 14...

Reviews: