Safety Measures in Case of Normal Operation 

 
The instrument must only be used by persons trained and instructed and being allowed to use it. They have 
to know the operating instructions and be able to work accordingly. 
 
Prior to each use, check the gun for visible damage and make sure that it is in perfect condition! Advise de-
tected defects to your superior at once! 
 
 
 
 
 

 

Safety Instructions for the Use of Holt-Melt Glue Gun TR 55 LCD

 

 

 

  Fill tank only up to 1.5 cm below upper rim. 

  Never exceed operating temperature of the hot melt. 

 

Overheating may lead to decomposition which may affect health. 

 

  Compressed air pressure max. 6 bars

 

  Once the gun has warmed up, nozzle and cover are extremely hot!

 

  Never start working without having mounted a nozzle.

 

  Do not direct glue jet towards people. 

  Prior to any nozzle replacement, unplug connecting cable.

 

*  

 

When replacing a nozzle, liquid glue might leak out. 

Warning: Risk of burning! 

*  

 

Never bring the hot nozzle into contact with the cable.

 

  

When your skin got into contact with hot glue, immediately cool it with cold water. 

    Do not try to remove hot melt from the skin first. If necessary consult your doctor. 

 

  

When hot adhesive got into your eyes, immediately cool them under running water for 

    about 15 minutes and consult your doctor at once. 

 

  If the vent valve does not audibly de-aerate, hot glue might flow off the sound absorber 

   after the trigger has been operated. 

 

  Always wear protective gloves!

 

 

Note:  - Do not lay gun on its side 
 

- Fill tank only up to max. 1.5 cm below upper rim 

 

- Gun must de-aerate audibly 

 

- Always de-aerate before lid is opened 

 

- Do not direct glue jet towards people 

 

- Do not hold nozzle top upwards 

 

- Never work without having mounted a nozzle 

 

- Do not carry out overhead work  

 

- Stop using the instrument, if casing is damaged due to shock, 

 

 

  breakage or heavy wear 

 

  Even if the gun has been switched off, it may be under pressure and glue may flow off.

 

 

 

 

 
 

 

 

Summary of Contents for TR55 LCD

Page 1: ...POWERBOND Art Nr 9109 Operating Instructions For The Powerbond TR55 LCD Total Melt Hot Melt Glue Gun...

Page 2: ...e of Contents Product Description 3 Trouble Shooting 4 General Safety Instructions 5 Start up 7 Operation 9 Additional Information 10 EC Conformity Certificate 11 Exploded Views 12 Spare Parts Legend...

Page 3: ...er s responsibility Technical Data Connection 230 V 110 V Heating capacity 400 W Air control glue 6 bars only in combination with a pressure controller A filter must be added Air consumption max 100 l...

Page 4: ...k controller check temperature replace valve Glue is too fluid or too con sistent temperature too high or too low check temperature Glue leaks out of nozzle sound absorber got stuck clogged nozzle spr...

Page 5: ...ng instructions and in particular the safety instructions Make the information available This operating manual shall be kept on the site of operation It must be ensured that all persons operating the...

Page 6: ...cable When replacing a nozzle liquid glue might leak out Warning Risk of burning Never bring the hot nozzle into contact with the cable When your skin got into contact with hot glue immediately cool...

Page 7: ...chosen temperature is not confirmed within a few seconds by pressing the key 3 the device will use the last chosen temperature While the device is heating up to the chosen temperature the numbers on...

Page 8: ...instrument temperature 60 80 C approx 140 175 F and empty For the replacement you need a SW 13 open end spanner You are advised to wear gloves Prior to exchanging nozzles unplug connecting cable Repla...

Page 9: ...t is fitted to a balancer Never lay gun on its side Open premelting tank only if required Keep hot melt free of dirt and humidity When using the stand remove wire strap General Hints Should the sound...

Page 10: ...malfunctions If you observe the operating instructions the gun does normally not need cleaning The glue remaining in the gun will remelt when it is warmed up and can be used for glueing again The glu...

Page 11: ...e been applied EN 60335 EN 292 EN 60204 HD 400 EN 55014 EN 60555 EN 61000 Design modifications influencing the technical data specified in the operating manual and the in tended use thus meaning a con...

Page 12: ...POWERBOND Art Nr 9109 12...

Page 13: ...9 2696 Membrane SEV 10 2697 90 fitting SEV 11 3130 Lid 12 2800 Disc 13 2801 Screw 14 2819 Sheet 15 2802 Intensification 16 2820 Distance 17 2603 O Ring 40x3 Viton 18 2613 Star grip 19 3665 Lock nut 2...