POWER FEED TESTING
Probe Tip Voltage.
Battery Voltage.
1
2
3
4
Down Arrow Indicates pressing the Down
Arrow will return to Ohm Meter
FEED TEST - Power Feed Test is used to
identify voltage drops on active circuits by
probing one connection of the circuit being
tested.
PFT displays both Battery and Tip voltage
simultaneously for easy voltage drop testing.
While testing, use the Aux. Ground and tip to
by-pass components. Place meter in line in
place of component and operate switches or
relays to close circuit.
In this mode, the
Maestro
™
display will show:
Ohm symbol displays and flashes if .5V
drop is exceeded showing that excessive
resistance may be present as corrosion or
other wire damage.