5.3.2
Bath and shower rooms
A
Zone 0
B
Zone 1
C
Zone 2
D
Window recess Zone 2
E
Ceiling
F
Outside zones
Important
Where an optional plug-in integral timer, RF receiver or thermostat
is NOT FITTED the boiler has a protection rating of IPX5D and if
installed in a room containing a bath or shower can be within Zone
2 (but not 0 or 1).
Important
A boiler fitted with an optional plug-in integral timer, RF receiver or
thermostat CANNOT be fitted in any zone.
Bathroom 1 and 2 ( in GB only) shows zone dimensions for a bathtub. For
other examples refer to the Current IEE Wiring Regulations). Reference
must be made to the relevant requirements.
In GB this is the current IEE. Wiring Regulations and Building Regulations.
In IE reference should be made to the current edition of IS 813 “Domestic
Gas Installations” and the current ETCI rules.
5.3.3
Ventilation
Where the appliance is installed in a cupboard or compartment, no air
vents are required. BS 5440: Part 2 refers to room sealed appliances in
stalled in compartments. The appliance will run sufficiently cool without
ventilation.
Fig.12
Bathroom 1 and 2
PN-0000400
A
B
C
D
D
0.6m
A
B
C
D
E
F
0.6m
2.25m