EMC TEST REPORT
Report No. : EC041208
SPORTON International Inc.
Page Number
: 41 of 63
TEL : 886-2-2696-2468
Issued Date
: Apr. 29, 2010
FAX : 886-2-2696-2255
10. Radio Frequency Electromagnetic Field Immunity Test (RS)
z
FINAL TEST RESULT
:
PASS
z
Pass Performance Criteria
:
A
z
Required Performance Criteria :
A
z
Basic Standard
:
IEC 61000-4-3:2002
z
Product Standard
:
EN 55024:1998/A1:2001/A2:2003
z
Level :
2
z
Frequency Range
:
80-1000 MHz
z
Additional Selection Frequency : 80, 120, 160, 230, 434, 460, 600, 863, 900MHz
z
Dwell Time
: 2.9 seconds
z
Field Strength
:
3 V/m (unmodulated, r.m.s) 80% AM (1 kHz)
z
Temperature :
25
℃
z
Relative Humidity
:
49 %
z
Atmospheric Pressure
:
103 kPa
z
Test Date
:
Apr. 26, 2010
z
Test Mode
:
Mode 1 ~ Mode 2
z
Observation :
Normal.
10.1. Test Setup
NOTE : The SPORTON 7m x 4m x 4m semichoic chamber is compliance with the sixteen points
uniform field requirement as stated in IEC 1000-4-3 Section 6.2.
The procedure defined in this part requires the generation of electromagnetic fields within which the test
sample is placed and its operation observed. To generate fields that are useful for simulation of actual (field)
conditions may require significant antenna drive power and the resultant high field strength levels. To
comply with local regulations and to prevent biological hazards to the testing personnel, it is recommended
that these tests be carried out in a shielded enclosure or semichoic chamber.