EMC TEST REPORT
Report No. : EC041208
SPORTON International Inc.
Page Number
: 50 of 63
TEL : 886-2-2696-2468
Issued Date
: Apr. 29, 2010
FAX : 886-2-2696-2255
12.2. Test Level
Level
Open-circuit test voltage,
±
10
%
, kV
1 0.5
2 1.0
3 2.0
4 4.0
x Specified
NOTE - x is an open class.
This level can be specified in the product specification.
12.3. Test Procedure
a. Climatic
conditions
The climatic conditions shall comply with the following requirements :
--
ambient temperature : 15
°
C to 35
°
C
--
relative humidity : 10 % to 75 %
--
atmospheric pressure : 86 kPa to 106 kPa ( 860 mbar to 1060 mbar )
b. Electromagnetic
conditions
The electromagnetic environment of the laboratory shall not influence the test results.
c.
The test shall be performed according the test plan that shall specify the test set-up with
--
generator and other equipment utilized;
--
test level ( voltage/current );
--
generator source impedance;
--
internal or external generator trigger;
--
number of tests : at least five positive and five negative at the selected points;
--
repetition rate : maximum 1/min.
--
inputs and outputs to be tested;
--
representative operating conditions of the EUT;
--
sequence of application of the surge to the circuit;
--
phase angle in the case of a.c. power supply;
--
actual installation conditions, for example :
AC : neutral earthed,
DC : ( + ) or ( - ) earthed to simulated the actual earthing conditions.