POSIFLEX DT-207 series User Manual Download Page 7

 

 

Part 7 

INSTALLING PD-201 (OPTION) 

Please first have a qualified technician to open 

the jumper setting service window on the bottom plate as 
marked in the left picture and set a DC + 5V support to 
the COM port that the PD-201 is to be connected to 
according to Posiflex technical information. 

Please then open the cable cover and push at the 

2 latches toward the 
system front as 
marked in the right 
picture to remove 

the UPS battery cover to show the UPS 
battery cavity as in the right picture below. 

Take the removed UPS battery 

cover as the below picture and push at the 
2 latches down to remove the customer 
display cover installed on it and result as 
the leftmost picture further below. 

 
 
 
 
 
 
 

 

 
Now take the PD-

201 and first pass its interface cable to go through the square opening in the 
UPS battery cover and insert the 2 lugs at front bottom of PD-201 as arrowed 
in the middle picture above into the correspondent positions arrowed in the 
leftmost picture above then press down the 2 latches on rear bottom of PD-201 
down till they firmly click in the UPS battery cover as in the rightmost picture 
above. Please double check if the PD-201 is well inserted. 

Before installing the PD-201 + UPS battery cover assembly into the 

DT system top cover, please check the bottom side 
of the PD-201 + UPS battery cover assembly to 
route the interface cable in between the guide posts 
on the UPS battery cover as indicated in the left 
picture. 

UPS 
Battery 
Cover 

PD Cover Taken Off 

PD-201 

Summary of Contents for DT-207 series

Page 1: ...a or profits resulting from furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential ha...

Page 2: ...ntenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the UPS battery as soon as the ...

Page 3: ...PICTURES Front View Inside Front Door Front Top View Rear Top View I Left Side View Rear Top View II Rear View Bottom View 21 24 12 20 22 26 27 13 23 25 19 14 11 16 17 17 16 10 18 15 15 1 15 8 12 14 10 13 2 9 11 3 4 1 3 4 5 7 2 6 ...

Page 4: ... option module cover 21 Display unit support steel wire rest ditch 22 Cable exit 23 Rubber feet 24 Jumper setting service window bracket 25 Jumper setting service window fixing screw 26 DRAM area bracket 27 DRAM area fixing screw PRODUCT FEATURES Standard Features a CPU AMD LX 700 b Fan free structure with delicately designed internal natural ventilation c Data storage device CF memory card defaul...

Page 5: ...LAN module 8 one CF card reader slot in front door o Support DDR SDRAM with maximum memory size 1GB in one SO DIMM module p Integrated structure for various option upgrade kit q Built in UPS function with battery option to support system from intermittent power failure internal speaker with 2 W audio amplifier r Accidental power off protection power switch resides inside front door and it can be p...

Page 6: ...des of the system unit circled in right picture to release the lower part of cable cover Please note that there are 2 plastic hooks on top edge of cable cover as rectangular marked in the picture holding the top cover at arrowed positions Push down the hooks to release the cable cover hook from the system top cover to show the connection area INSTALLING UPS BATTERY OPTION The UPS battery is in the...

Page 7: ...n it and result as the leftmost picture further below Now take the PD 201 and first pass its interface cable to go through the square opening in the UPS battery cover and insert the 2 lugs at front bottom of PD 201 as arrowed in the middle picture above into the correspondent positions arrowed in the leftmost picture above then press down the 2 latches on rear bottom of PD 201 down till they firml...

Page 8: ...D 309 is to be connected to according to Posiflex technical information if it is the RS232 interface model PD 309 The LCD customer display PD 309 or PD 309U can be attached to either rear corner of bottom plate Refer to the pictures above Apply the metal base plate of PD 309 U from bottom of DT 207 208 allowing the rubber foot at that corner of DT 207 208 to be in the circled hole Use the 3 attach...

Page 9: ...put on the transparent key cap from the accessories In this way the labeling will be protected and resistant to scratch or rubbing The numerical keypad part of the keystroke type keyboard is preprinted with laser printed keys without the transparent key cap When re labeling of programmable key is required please use the attached key clip to hook up the transparent key cap and change the label then...

Page 10: ...ottom of cable cover Please make sure that each connector has to be connected to the right device in the right way CAUTION On doing any insertion or extraction of any connector please always hold the connector head itself instead of pulling on the cable wire Failure to do this could damage the cable and jack that is considered as an artificial destruction and is not covered by the warranty OPERATI...

Page 11: ...iflex com tw Then follow instructions from your system integrator for software recovery OPERATING SYSTEM INSTALLATION This product is a highly professional equipment The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user or obstacle by possibly unintentional negligence even for PC veterans to accomplish such a task Therefore OS installa...

Page 12: ...ep the external power adaptor in a free air circulation UPS Battery option General care The UPS battery is consumable beyond product warranty Please definitely observe the alerts in beginning of this manual If the equipment is to be powered off for more than few days please always disconnect the battery from the system Reconnect it and turn on the system to recharge the battery for 1 2 hours every...

Page 13: ...If there are any signs of over charging or leakage of electrolyte please contact your dealer immediately POWER ON OFF Touch Open Front Door A gentle tap on the touch open front door at front side of the main unit will open the cover and show the power switch and a CF memory card reader slot It is preferable to keep this door closed through daily operation There must always be at least 10 seconds w...

Page 14: ...gain the forced power off feature will not work in this mode When using this feature please make sure that the software application has the ability to power off the machine In preloaded Windows Posiflex Power Switch Manager in Posiflex Tools in the Program Files helps managing these functions Software Support Features The DT system provides a software power off command for application program mane...

Page 15: ...4 MB can be shared as the video memory CUSTOMER DISPLAY OPTION Please follow the instructions on the manual that comes along with the customer display when it is installed SERIAL PORTS COM1 2 3 4 There are 4 serial ports available in form of DB9 All serial ports can supply a 5 V DC through pin 9 and or a 12 V DC through pin 1 after proper jumper setting change It is very important to discontinue t...

Page 16: ...s without touch panel i e DT 207 can ignore them and consider this user s manual ends here Mechanical Support The mechanical structure of the display unit in DT system can hold the display unit firmly for DT 207 However for the touch function in DT 208 extra support of a steel wire is required to offset the external touch force Please pick the display unit support steel wire from its rest ditch on...

Page 17: ...ad from the POSIFLEX web site Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in the preloaded Windows system with a USB interface touch panel controller This program can also be obtained by download from the POSIFLEX web site Emergency Power Off In case of serious system halt due ...

Page 18: ...Part 18 ...

Page 19: ...Part 19 ...

Page 20: ...Part 20 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 警告 本電池如果更換不正確會有爆炸的危險 請依製造商說明書處理用過之電池 ...